Sterilite Test Isolatörü
- Dedicated Sterility Test Layout
- Dual-Operator Glove Access
- Controlled Sample Transfer
- Separated Waste Removal
Ürün tanıtımı
The sterility test isolator separates test samples and media from operators and the surrounding laboratory. One or two glove-access work chambers can support membrane filtration, direct inoculation or compatible rapid methods. Samples enter through a bio-decontamination hatch or rapid transfer port, and liquid and solid waste leave through dedicated closed routes. The chamber uses filtered airflow, welded stainless surfaces and pressure monitoring to maintain the selected test environment and reduce false-positive contamination risk.
Ana Özellikler
A dedicated transfer hatch separates load preparation from the main test chamber.
Separate liquid and solid waste interfaces prevent waste crossing the clean sample route.
A common control system monitors pressure, airflow and optional bio-decontamination cycles.
Radiused stainless interiors keep membrane-filtration equipment accessible for cleaning.
Uygulamanız için çözümler
Sterility testing needs both contamination prevention and a workflow that keeps sample entry, test manipulation and waste removal from crossing each other.
Tipik uygulamalar
Teknik parametreler
Typical configurable construction ranges for a sterility test isolator are listed below.
| Temel malzemeler | Fully welded SUS316L test chamber with laminated safety glass and CSM glove-sleeve assemblies |
|---|---|
| Panel kalınlığı | 50-100 mm double-skin chamber and air-handling sections |
| Effective Width (Etkili Genişlik) | 1800-4500 mm usable test-chamber width |
| Maksimum uzunluk | Up to 6500 mm overall isolator length |
| Çelik yüz yüze kalınlığı | 2.0-3.0 mm SUS316L chamber shell; 1.2-1.5 mm service skins |
| Core Density (Çekirdek Yoğunluğu) | SUS316L oda malzemesi için yaklaşık 8000 kg/m³ |
| Termal İletkenlik | Östenitik paslanmaz çelik için 14-16 w/(m · k) |
| Yüzey bitirme | Electropolished SUS316L test chamber with welded radiused transitions |
| Ortak tip | Pressure-tight welded chamber with sealed glove rings, transfer hatch and separate waste interfaces |
| Customization (Özelleşme) | Kullanılan uygulama ve çalışma ortamına göre kullanılabilir. |
Mevcut Seçenekler
Planning a Sterility Test Isolator specification?
Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

İngilizce
Portekizce
İspanyolca
Malay dilinde
Endonezya dilinde
Almanca
TürkçeCurrent
Vietnamca
Fransızca
Rusça
Arapça
Taylandca
Japonca
Korece