클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
/ 제품 / 클린룸 장비 / Operating Room Laminar Flow Ceiling 3489 × 3559 mm Large Format
STJH-OPERATING-ROOM-LAMINAR-CEILING-3489

Operating Room Laminar Flow Ceiling 3489 × 3559 mm Large Format

The broadest cited surgical canopy, intended for major orthopaedic and implant theatres with extensive sterile-zone equipment.
  • 3489 x 3559 mm maximum field
  • 11180 m³/h clean-air duty
  • Broad major-surgery coverage
견적 요청 제품 찾아보기

상품 소개

This 3489 x 3559 mm canopy creates the largest protected field in the operating-room series. It delivers a cited 11180 m³/h of clean air with 6480 m³/h recirculation, providing space for the table, surgical team and adjacent sterile equipment. The slightly rectangular plan helps cover long procedure layouts common in orthopaedic and implant work.

주요 기능

Extended sterile footprint

The near-3.5 m field covers long tables, instrument positions and larger surgical teams.

High clean-air capacity

The 11180 m³/h cited duty supports the broader discharge area without treating it as a small canopy.

Major-theatre layout

The rectangular geometry is suited to orthopaedic, implant and equipment-intensive operating rooms.

기술 매개변수

Airflow Field3489 x 3559 mm
Clean Airflow11180 m³/h
Recirculation Airflow6480 m³/h
Final Filter ClassH14
DischargeLow-turbulence downward air
Protected ZoneLarge operating table and equipment footprint
Installation TypeIntegrated operating-room ceiling
Typical ProceduresOrthopaedic and implant surgery
System BalanceEngineered with room supply and return air
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

Applications

For major orthopaedic, implant and other equipment-intensive theatres requiring a broad clean-air zone. Structural support and service coordination are particularly important at this canopy size.

Solutions for Your Application

Instrument tables or imaging components extend beyond a standard square canopy.Use the larger 3489 x 3559 mm field to encompass the planned sterile footprint.
A wide ceiling field can become uneven if air distribution is not zoned.Coordinate filter modules, supply plenums and room returns to balance the entire outlet area.

사용 가능한 옵션

Configure outlet zones, light openings, service-bridge interfaces, recirculation modules, filter access and structural suspension. Final performance is set by theatre calculations.

Planning a Operating Room Laminar Flow Ceiling 3489 × 3559 mm Large Format specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat

제품

뉴스

회사 소개

문의하기