موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
الرئيسية / المنتجات / معدات الغرف النظيفة / Operating Room Laminar Flow Ceiling 3489 × 3559 mm Large Format
STJH-OPERATING-ROOM-LAMINAR-CEILING-3489

Operating Room Laminar Flow Ceiling 3489 × 3559 mm Large Format

The broadest cited surgical canopy, intended for major orthopaedic and implant theatres with extensive sterile-zone equipment.
  • 3489 x 3559 mm maximum field
  • 11180 m³/h clean-air duty
  • Broad major-surgery coverage
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This 3489 x 3559 mm canopy creates the largest protected field in the operating-room series. It delivers a cited 11180 m³/h of clean air with 6480 m³/h recirculation, providing space for the table, surgical team and adjacent sterile equipment. The slightly rectangular plan helps cover long procedure layouts common in orthopaedic and implant work.

الخصائص الرئيسية

Extended sterile footprint

The near-3.5 m field covers long tables, instrument positions and larger surgical teams.

High clean-air capacity

The 11180 m³/h cited duty supports the broader discharge area without treating it as a small canopy.

Major-theatre layout

The rectangular geometry is suited to orthopaedic, implant and equipment-intensive operating rooms.

المعلمات الفنية

Airflow Field3489 x 3559 mm
Clean Airflow11180 m³/h
Recirculation Airflow6480 m³/h
Final Filter ClassH14
DischargeLow-turbulence downward air
Protected ZoneLarge operating table and equipment footprint
Installation TypeIntegrated operating-room ceiling
Typical ProceduresOrthopaedic and implant surgery
System BalanceEngineered with room supply and return air
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

For major orthopaedic, implant and other equipment-intensive theatres requiring a broad clean-air zone. Structural support and service coordination are particularly important at this canopy size.

Solutions for Your Application

Instrument tables or imaging components extend beyond a standard square canopy.Use the larger 3489 x 3559 mm field to encompass the planned sterile footprint.
A wide ceiling field can become uneven if air distribution is not zoned.Coordinate filter modules, supply plenums and room returns to balance the entire outlet area.

الخيارات المتاحة

Configure outlet zones, light openings, service-bridge interfaces, recirculation modules, filter access and structural suspension. Final performance is set by theatre calculations.

Planning a Operating Room Laminar Flow Ceiling 3489 × 3559 mm Large Format specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat