상품 소개

This wall-mounted pass box provides a dedicated route for small materials without moving personnel between rooms. A double-wall body keeps the door linkage outside the usable transfer space, while a flat stainless floor gives trays a continuous sliding surface. The enclosed chamber can be reached from either room for wiping, and glazed doors allow staff to see whether a load remains inside. It is a passive barrier between sequential door openings, not an air-treatment cabinet.

주요 기능

Protected linkage keeps the locking mechanism away from routine loading impacts.

The uninterrupted sill reduces obstacles when moving shallow trays.

Windowed doors let staff check occupancy before reaching into the cabinet.

Replaceable closure seals allow wear points to be serviced separately.

A mechanical interlock can be selected where powered accessories are unnecessary.

응용 프로그램 솔루션

Choose the hatch around the physical transfer task and the way its two sides will be operated.

Staff carry small supplies through a full-sized room doorway.A dedicated hand-transfer opening avoids that unnecessary personnel movement.
Both sides are opened while a container is still being handled.Select interlocking hardware that holds the opposite door closed during access, with a clear recovery method for faults.
Long trays fit inside but strike the doorway or latch.Check the actual clear aperture, hinge intrusion and tray grip space rather than buying on chamber volume alone.
Powder or packaging debris collects around internal fittings.Keep the usable floor clear of exposed linkage and select corner and sill details that can be reached during wiping.

일반적인 응용 프로그램

Wrapped packaging supplies between compatible clean areasSmall medical-device components in covered traysElectronics tools and assembly fixturesClosed laboratory sample containers

Use the static arrangement for a transfer route whose material preparation is handled separately. It does not sterilize packaging, remove airborne contamination within the chamber or provide hazardous-material containment.

기술 매개변수

The following are commonly selectable construction references for passive transfer cabinets, not measured specifications of a particular STjh assembly. Chamber dimensions describe the usable enclosure; the wall opening and external body require additional space.

전송 원리Passive two-door chamber without a circulation fan or HEPA air-cleaning stage
Internal Chamber Size References500 × 500 × 500, 600 × 600 × 600 or 800 × 800 × 800 mm, W × D × H
챔버 재질304 stainless steel; 316L construction selectable
Enclosure Sheet References1.0 or 1.2 mm stainless sheet for selected body and liner parts
문 배열Opposed manually operated doors with viewing windows
Interlock SelectionMechanical linkage or electrically controlled one-door-at-a-time locking
Closure ComponentsPerimeter door gasket and compression-latch arrangement
인테리어 건설Smooth transfer floor with accessible corners and concealed interlock hardware
Mounting ArrangementThrough-wall cabinet with perimeter finishing frames
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Mechanical or electronic door interlock304 or 316L stainless constructionOpaque or windowed doorsAlternative chamber proportionsWall-depth finishing framesSupport stand for the handling height

The normal starting point is a stainless chamber with two gasketed doors and a selected interlock. Powered status indication and access-control functions can be added with the electrical version. Dimensions and mounting details can be customized without introducing a fan or filtration stage into the passive transfer principle.

Selection and Installation

Size the opening around the largest tray or container, including its handles and the operator's grip. The clear door aperture can be smaller than the chamber, so a nominal 600 mm cube is not a promise that a 600 mm-wide load will pass through. Locate the transfer floor at a comfortable handling height and support the cabinet independently of lightweight wall finishes where necessary.

A passive hatch does not clean the material or replace the room's pressure-control system. Use it with a defined exterior-wiping and packaging-transfer practice. Where the transfer process also needs an internal filtered-air cycle, compare the HEPA-filtered dynamic pass box rather than adding a blower specification to this static model.