Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Trang chủ / Sản phẩm / Cleanroom HVAC Systems / Water-Cooled Centrifugal Chiller 1407 kW
STJH-WATER-COOLED-CHILLER-1407KW

Water-Cooled Centrifugal Chiller 1407 kW

A mid-capacity water-cooled centrifugal chiller producing 1407 kW with a 5053 mm-long heat-exchanger frame.
  • 1407 kW cooling output
  • 60.49 l/s evaporator flow
  • 5053 mm heat-exchanger length
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

The 1407 kW selection lengthens the heat-exchanger package to 5053 mm and raises evaporator flow to 60.49 l/s. Its published 200.5 kW input suits larger pharmaceutical and electronics plants that have moved beyond the smallest centrifugal frame but do not require the 2110 kW machine.

Các tính năng chính

Mid-capacity plant fit

The machine fills the capacity gap between a medium building chiller and the largest campus-scale selection.

Longer heat-transfer surface

The extended frame accommodates the evaporator and condenser area required for the higher water flow.

Published power reference

A 200.5 kW input point supports electrical and energy planning at the stated cooling condition.

Thông số kỹ thuật

Cooling Capacity1407 kW
Input Power200.5 kW
Evaporator Flow60.49 l/s
Dimensions5053 x 2469 x 2852 mm
Compressor TypeCentrifugal
EvaporatorShell-and-tube water circuit
CondenserWater-cooled shell-and-tube circuit
Capacity ControlModulating chiller control
InstallationIndoor central plant-room base
Tùy chỉnhWater-box connections, electrical supply and control interface can be configured for the intended application and operating environment.

Applications

Larger pharmaceutical plants, electronics manufacturing, hospital campuses and clean production facilities with central cooling towers.

Solutions for Your Application

The 1055 kW frame leaves insufficient capacity for the calculated simultaneous load.Use the 1407 kW selection after applying the facility's staging and resilience allowance.
The longer chiller may restrict tube service within the plant room.Reserve the full 5053 mm equipment length plus the required heat-exchanger tube-removal clearance.

Các tùy chọn có sẵn

Water-box orientation, pressure rating, electrical starter, isolation, heat recovery, flow instrumentation and plant-control communication are available.

Planning a Water-Cooled Centrifugal Chiller 1407 kW specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Nói chuyện với đội ngũ của chúng tôi
Email cho chúng tôi WhatsApp WeChat