موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
الرئيسية / المنتجات / Cleanroom HVAC Systems / Water-Cooled Centrifugal Chiller 1407 kW
STJH-WATER-COOLED-CHILLER-1407KW

Water-Cooled Centrifugal Chiller 1407 kW

A mid-capacity water-cooled centrifugal chiller producing 1407 kW with a 5053 mm-long heat-exchanger frame.
  • 1407 kW cooling output
  • 60.49 l/s evaporator flow
  • 5053 mm heat-exchanger length
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The 1407 kW selection lengthens the heat-exchanger package to 5053 mm and raises evaporator flow to 60.49 l/s. Its published 200.5 kW input suits larger pharmaceutical and electronics plants that have moved beyond the smallest centrifugal frame but do not require the 2110 kW machine.

الخصائص الرئيسية

Mid-capacity plant fit

The machine fills the capacity gap between a medium building chiller and the largest campus-scale selection.

Longer heat-transfer surface

The extended frame accommodates the evaporator and condenser area required for the higher water flow.

Published power reference

A 200.5 kW input point supports electrical and energy planning at the stated cooling condition.

المعلمات الفنية

Cooling Capacity1407 kW
Input Power200.5 kW
Evaporator Flow60.49 l/s
Dimensions5053 x 2469 x 2852 mm
Compressor TypeCentrifugal
EvaporatorShell-and-tube water circuit
CondenserWater-cooled shell-and-tube circuit
Capacity ControlModulating chiller control
InstallationIndoor central plant-room base
التخصيصWater-box connections, electrical supply and control interface can be configured for the intended application and operating environment.

Applications

Larger pharmaceutical plants, electronics manufacturing, hospital campuses and clean production facilities with central cooling towers.

Solutions for Your Application

The 1055 kW frame leaves insufficient capacity for the calculated simultaneous load.Use the 1407 kW selection after applying the facility's staging and resilience allowance.
The longer chiller may restrict tube service within the plant room.Reserve the full 5053 mm equipment length plus the required heat-exchanger tube-removal clearance.

الخيارات المتاحة

Water-box orientation, pressure rating, electrical starter, isolation, heat recovery, flow instrumentation and plant-control communication are available.

Planning a Water-Cooled Centrifugal Chiller 1407 kW specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا