Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Trang chủ / Sản phẩm / Cleanroom Air Filters / V-Bank Activated Carbon Filter 592 × 592 mm
STJH-VBANK-CARBON-FILTER-592X592

V-Bank Activated Carbon Filter 592 × 592 mm

A full-square activated-carbon V-bank delivering 3400 m3/h for standard 610 mm-class air-handler modules.
  • 3400 m3/h full module
  • 592 mm square face
  • 80 Pa initial drop
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

This 592 x 592 x 300 mm cartridge is the full-module choice in the frozen V-bank carbon group. Its larger face supports 3400 m3/h at an initial 80 Pa, allowing a standard square rack to carry the highest airflow of the three sizes. The molded frame holds pleated molecular media for gaseous contaminants; it is not a substitute for prefiltration or final HEPA filtration. Carbon grade and replacement timing must follow the actual ozone, acid-gas and VOC exposure.

Các tính năng chính

Standard full-cell integration

The 592 mm square face fits common 610 mm-class holding frames, simplifying molecular-stage layout in new full-size AHU banks.

Maximum family airflow

A rated 3400 m3/h makes this the highest-capacity size in the three-model V-bank group while maintaining the documented 80 Pa starting drop.

Upgrade-friendly molecular stage

Compact pleated adsorbent can add gas control to suitable existing front- or side-access installations without using a loose-fill deep bed.

Thông số kỹ thuật

Dimensions592 x 592 x 300 mm
Rated Airflow3400 m3/h
Initial Pressure Drop80 Pa
Molecular MediaBroad-spectrum activated carbon
Target ContaminantsOzone, NO2, SO2 and VOCs
Frame ConstructionMolded plastic V-bank
SealOne-piece polyurethane gasket
Maximum Operating Temperature40 C
Maximum Relative Humidity70% RH
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Applications

For full-module supply or recirculation banks serving semiconductor facilities, healthcare ventilation, laboratories and other clean-air systems exposed to mixed low-level gases. Use particulate stages as required and size the carbon life from measured loading rather than a fixed calendar interval.

Solutions for Your Application

A full airflow row could require too many smaller molecular cartridges and joints.Use the 3400 m3/h square module where the rack accepts 592 x 592 mm filters, reducing cell count and the number of potential bypass interfaces.
Molecular performance may fall early in warm or humid outside air.Keep the operating environment within the selected media limits and include temperature, humidity and contaminant concentration in the service-life calculation.

Các tùy chọn có sẵn

Select target-gas carbon, gasket orientation, front or side access, particulate prefilter grade, monitoring method and staged media arrangement for mixed contaminants.

Planning a V-Bank Activated Carbon Filter 592 × 592 mm specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Nói chuyện với đội ngũ của chúng tôi
Email cho chúng tôi WhatsApp WeChat