STJH-VBANK-CARBON-FILTER-592X592

V-Bank Activated Carbon Filter 592 × 592 mm

A full-square activated-carbon V-bank delivering 3400 m3/h for standard 610 mm-class air-handler modules.
  • 3400 m3/h full module
  • 592 mm square face
  • 80 Pa initial drop
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This 592 x 592 x 300 mm cartridge is the full-module choice in the frozen V-bank carbon group. Its larger face supports 3400 m3/h at an initial 80 Pa, allowing a standard square rack to carry the highest airflow of the three sizes. The molded frame holds pleated molecular media for gaseous contaminants; it is not a substitute for prefiltration or final HEPA filtration. Carbon grade and replacement timing must follow the actual ozone, acid-gas and VOC exposure.

الخصائص الرئيسية

Standard full-cell integration

The 592 mm square face fits common 610 mm-class holding frames, simplifying molecular-stage layout in new full-size AHU banks.

Maximum family airflow

A rated 3400 m3/h makes this the highest-capacity size in the three-model V-bank group while maintaining the documented 80 Pa starting drop.

Upgrade-friendly molecular stage

Compact pleated adsorbent can add gas control to suitable existing front- or side-access installations without using a loose-fill deep bed.

المعلمات الفنية

Dimensions592 x 592 x 300 mm
Rated Airflow3400 m3/h
Initial Pressure Drop80 Pa
Molecular MediaBroad-spectrum activated carbon
Target ContaminantsOzone, NO2, SO2 and VOCs
Frame ConstructionMolded plastic V-bank
SealOne-piece polyurethane gasket
Maximum Operating Temperature40 C
Maximum Relative Humidity70% RH
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

For full-module supply or recirculation banks serving semiconductor facilities, healthcare ventilation, laboratories and other clean-air systems exposed to mixed low-level gases. Use particulate stages as required and size the carbon life from measured loading rather than a fixed calendar interval.

Solutions for Your Application

A full airflow row could require too many smaller molecular cartridges and joints.Use the 3400 m3/h square module where the rack accepts 592 x 592 mm filters, reducing cell count and the number of potential bypass interfaces.
Molecular performance may fall early in warm or humid outside air.Keep the operating environment within the selected media limits and include temperature, humidity and contaminant concentration in the service-life calculation.

الخيارات المتاحة

Select target-gas carbon, gasket orientation, front or side access, particulate prefilter grade, monitoring method and staged media arrangement for mixed contaminants.

Planning a V-Bank Activated Carbon Filter 592 × 592 mm specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا