The smallest EV cabinet for balanced fresh-air ventilation in low-occupancy support rooms.
  • 40-110 CFM airflow
  • Single static enthalpy core
  • Indoor any-orientation mounting
Solicite un presupuesto. Browse productos

Introducción del producto

This compact energy recovery ventilator covers 40-110 CFM with one static enthalpy core and small direct-drive fans. Indoor any-orientation installation and a low-voltage control circuit allow the cabinet to fit local support offices, laboratories and low-occupancy controlled rooms. The static core has no wheel drive, but filters, condensate conditions, air balance and exhaust-air suitability still require routine attention.

Características clave

Small balanced ventilation

The cabinet introduces outdoor air while exhausting a similar local room airflow.

No rotating recovery wheel

A fixed plate core transfers total energy without a belt or wheel motor.

Flexible indoor placement

The compact enclosure can be oriented to suit available service and duct routing.

Parámetros técnicos

Airflow Range40-110 CFM
InstallationIndoor, any orientation
Recovery CoreOne static enthalpy core
FansCompact direct drive
ControlsLow-voltage control circuit
Air StreamsBalanced outdoor and exhaust air
RecoverySensible and latent
FiltrationSupply and exhaust filters by selection
Primary DutySmall support-room ventilation
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Applications

For small clean-support offices, laboratories and low-occupancy controlled rooms requiring local outdoor-air ventilation.

Solutions for Your Application

A small imbalance disrupts room pressure relative to the adjacent clean area.Measure both airstreams at the installed external pressure and trim fan or damper settings to the pressure plan.
An unsuitable exhaust contaminant crosses through the enthalpy core.Review exhaust compatibility and use a separated sensible-only recovery method where transfer risk is unacceptable.

Opciones disponibles

Confirm supply and exhaust duties, voltage, controls, filters, duct orientation, balancing, frost strategy, access and mounting.

Planning a Energy Recovery Ventilator 110 CFM specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto