Ducha de aire limpio para una sola persona
- One-Person Footprint
- Directional Garment Jets
- Interlocked Door Sequence
- Low-Level Particle Return
Introducción del producto
This cleanroom air shower provides a controlled transition between a gowning room and a clean area. After entry, the door sequence holds the passage closed while sidewall nozzles direct filtered air across the operator; released lint is collected through lower return grilles before the air is recirculated. Its compact straight-through layout is intended for single-file personnel traffic where entrance space is limited.
Características clave
Adjustable nozzle rows can be aimed at sleeves, torso and lower garments.
Lower return grilles collect recirculating air and released lint near the chamber floor.
A timed controller coordinates the cleaning period and the door-release sequence.
Smooth internal panels allow routine wipe-down of the occupied chamber surfaces.
Soluciones para su aplicación
A single-occupant entry needs repeatable garment cleaning without consuming valuable gowning-room space or creating confusing door operation.
Aplicaciones típicas
Parámetros técnicos
Common compact configurations for individual cleanroom entry. Overall and clear-chamber dimensions are paired by layout; single-side and opposing-side nozzle arrangements are separate options.
| Ocupación | One person per shower cycle |
|---|---|
| Passage Arrangement | Straight-through personnel entry with a door at each end |
| Common Single-Side Layout Option | Overall: 1260 × 1000 × 2050 mm; clear chamber: 790 × 930 × 1910 mm (W × D × H) |
| Common Opposing-Side Layout Option | Overall: 1400 × 1000 × 2100 mm; clear chamber: 800 × 900 × 1980 mm (W × D × H) |
| Nozzle Configuration Options | 6 nozzles for single-side delivery or 12 nozzles for opposing-side delivery |
| Common Jet-Velocity Reference | Approximately 25 m/s at the nozzle outlets |
| Timer Range Option | 0–99 s adjustable shower timer |
| Enclosure Choices | Powder-coated steel, Type 304 stainless steel or a painted exterior with stainless interior |
| Disposición del filtro | Prefilter and HEPA final filtration in a recirculating air circuit |
| Return-Air Position | Low-wall return grilles |
| Common Mains-Supply Option | 380 V AC, 50 Hz |
| Cycle and Door Controls | Timed shower operation and interlocked entrance/exit sequence; emergency-release configuration available |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Selection and Installation
Fit the entrance, not just the cabinet
Use the clear chamber dimensions to assess a fully gowned user's movement, then check the actual door aperture and threshold separately. Reserve space for both door swings, adjacent benches and filter removal. A compact shell is useful only when the operator can pass through without brushing the doorway or blocking the gowning route.
Choose the nozzle arrangement
A single-side configuration keeps its outlets on one wall; opposing-side delivery uses a different air circuit and nozzle count. Set nozzle direction and the operator's turning routine together. Outlet velocity is a jet measurement, not the average chamber velocity or a guaranteed particle-removal percentage. For a specifically bilateral configuration, compare the double-sided single-person air shower.
Set the operating sequence
Choose a useful nonzero shower duration within the supplied controller range. Entry detection, door closure, showering and exit release are separate events; a timer setting does not describe the complete entry time. Define normal interlocking, emergency release and power-failure behavior independently.
Keep service access usable
Locate the filter and blower access before surrounding partitions are finished. Include the actual fan, lighting, controls and any door operators in the electrical schedule rather than assuming a motor rating equals total demand. Keep lower returns accessible for cleaning, and select the final filter, seals and replacement parts as one compatible assembly.
Planning a Single-Person Cleanroom Air Shower specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Inglés