STJH-ENERGY-RECOVERY-VENTILATOR-110CFM

Energy Recovery Ventilator 110 CFM

The smallest EV cabinet for balanced fresh-air ventilation in low-occupancy support rooms.
  • 40-110 CFM airflow
  • Single static enthalpy core
  • Indoor any-orientation mounting
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This compact energy recovery ventilator covers 40-110 CFM with one static enthalpy core and small direct-drive fans. Indoor any-orientation installation and a low-voltage control circuit allow the cabinet to fit local support offices, laboratories and low-occupancy controlled rooms. The static core has no wheel drive, but filters, condensate conditions, air balance and exhaust-air suitability still require routine attention.

الخصائص الرئيسية

Small balanced ventilation

The cabinet introduces outdoor air while exhausting a similar local room airflow.

No rotating recovery wheel

A fixed plate core transfers total energy without a belt or wheel motor.

Flexible indoor placement

The compact enclosure can be oriented to suit available service and duct routing.

المعلمات الفنية

Airflow Range40-110 CFM
InstallationIndoor, any orientation
Recovery CoreOne static enthalpy core
FansCompact direct drive
ControlsLow-voltage control circuit
Air StreamsBalanced outdoor and exhaust air
RecoverySensible and latent
FiltrationSupply and exhaust filters by selection
Primary DutySmall support-room ventilation
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

For small clean-support offices, laboratories and low-occupancy controlled rooms requiring local outdoor-air ventilation.

Solutions for Your Application

A small imbalance disrupts room pressure relative to the adjacent clean area.Measure both airstreams at the installed external pressure and trim fan or damper settings to the pressure plan.
An unsuitable exhaust contaminant crosses through the enthalpy core.Review exhaust compatibility and use a separated sensible-only recovery method where transfer risk is unacceptable.

الخيارات المتاحة

Confirm supply and exhaust duties, voltage, controls, filters, duct orientation, balancing, frost strategy, access and mounting.