Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Laman Utama / Produk / Cleanroom HVAC Systems / Energy Recovery Ventilator 110 CFM
STJH-ENERGY-RECOVERY-VENTILATOR-110CFM

Energy Recovery Ventilator 110 CFM

The smallest EV cabinet for balanced fresh-air ventilation in low-occupancy support rooms.
  • 40-110 CFM airflow
  • Single static enthalpy core
  • Indoor any-orientation mounting
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

This compact energy recovery ventilator covers 40-110 CFM with one static enthalpy core and small direct-drive fans. Indoor any-orientation installation and a low-voltage control circuit allow the cabinet to fit local support offices, laboratories and low-occupancy controlled rooms. The static core has no wheel drive, but filters, condensate conditions, air balance and exhaust-air suitability still require routine attention.

Ciri-ciri Utama

Small balanced ventilation

The cabinet introduces outdoor air while exhausting a similar local room airflow.

No rotating recovery wheel

A fixed plate core transfers total energy without a belt or wheel motor.

Flexible indoor placement

The compact enclosure can be oriented to suit available service and duct routing.

Parameter teknikal

Airflow Range40-110 CFM
InstallationIndoor, any orientation
Recovery CoreOne static enthalpy core
FansCompact direct drive
ControlsLow-voltage control circuit
Air StreamsBalanced outdoor and exhaust air
RecoverySensible and latent
FiltrationSupply and exhaust filters by selection
Primary DutySmall support-room ventilation
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Applications

For small clean-support offices, laboratories and low-occupancy controlled rooms requiring local outdoor-air ventilation.

Solutions for Your Application

A small imbalance disrupts room pressure relative to the adjacent clean area.Measure both airstreams at the installed external pressure and trim fan or damper settings to the pressure plan.
An unsuitable exhaust contaminant crosses through the enthalpy core.Review exhaust compatibility and use a separated sensible-only recovery method where transfer risk is unacceptable.

Pilihan yang boleh didapati

Confirm supply and exhaust duties, voltage, controls, filters, duct orientation, balancing, frost strategy, access and mounting.

Planning a Energy Recovery Ventilator 110 CFM specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami