Inicio / Productos / Containment & Biosafety Equipment / Class II Type B2 Biological Safety Cabinet 1200 mm
STJH-CLASS-II-TYPE-B2-BIOLOGICAL-SAFETY-CABINET-1200

Class II Type B2 Biological Safety Cabinet 1200 mm

A four-foot Class II Type B2 cabinet with a dedicated 254 mm exhaust connection and 100% facility exhaust.
  • 100% total exhaust
  • 254 mm exhaust connection
  • Four-foot enclosure
Solicite un presupuesto. Browse productos

Introducción del producto

This compact B2 model sends all cabinet air to the facility exhaust rather than recirculating it to the room. The 1379 mm exterior width provides a focused work zone for suitable volatile or hazardous procedures while limiting the footprint and exhaust demand relative to the six-foot unit.

Características clave

No room recirculation

All cabinet airflow leaves through the hard-duct exhaust route.

Defined duct interface

A dedicated 254 mm connection supports facility system planning.

Compact B2 footprint

The four-foot format suits focused processes that do not need the 1800 mm work width.

Parámetros técnicos

Exterior Dimensions1379 x 803 x 1816 mm
Cabinet ClassClass II Type B2
Exhaust Architecture100% total exhaust
Exhaust Connection254 mm
Inflow VelocityApproximately 0.53 m/s
Downflow VelocityApproximately 0.28 m/s
Facility ConnectionHard duct
Work-Zone UseFocused volatile or hazardous process
Nominal Size1200 mm / 4 ft
CustomizationDuct transition, services and base can be configured for the facility exhaust and process.

Applications

Suitable biological work involving limited volatile chemicals or hazardous-drug processes requiring total cabinet exhaust.

Solutions for Your Application

Recirculated exhaust is inappropriate for the selected process.Use the Type B2 architecture and discharge all cabinet air through the facility duct.
The building system must maintain cabinet exhaust stability.Coordinate the 254 mm connection and airflow controls with the facility exhaust design.

Opciones disponibles

Duct transition, services, base stand and exhaust monitoring interface can be configured.

Planning a Class II Type B2 Biological Safety Cabinet 1200 mm specification?