Sistema de alarma central de sala limpia

A dedicated alarm annunciation platform that consolidates room, equipment, door and utility events into prioritized visual, audible and remote notifications.
  • Priority-Based Annunciation
  • First-Out Event Capture
  • Zone Alarm Mapping
  • Remote Notification Outputs
Solicite un presupuesto. Browse productos

Introducción del producto

The cleanroom central alarm system receives dry contacts, analog alarm states and network events from environmental instruments and supporting equipment. A color touchscreen and physical audible-visual devices distinguish critical alarms from warnings and maintenance notices. First-out sequencing identifies the initiating event before secondary conditions appear, while acknowledgement, silence and reset remain separate operator actions. Local alarm panels can be distributed by suite and connected to a central workstation without replacing the independent alarm functions at each room.

Características clave

First-out chronology highlights the event that initiated a chain of related alarms.

Distinct colors and sound patterns separate critical, warning and advisory priorities.

Zone maps direct responders to the affected room, airlock, utility or equipment item.

Isolated relay and network outputs route selected alarms to BMS, EMS or remote dialers.

Soluciones para su aplicación

A central alarm system must make the first actionable condition obvious without suppressing local room-level warnings.

Many alarms appear together and operators cannot identify the initiating fault.First-out sequencing and synchronized timestamps preserve the original event order.
All events use the same buzzer and receive the same response.Priority-specific colors, sounds and routing distinguish urgent excursions from maintenance notices.
Responders know an alarm exists but not where it originated.Room and equipment maps connect each alarm point to a clear physical location.
Silencing a horn is confused with clearing the alarm condition.Separate acknowledge, silence and reset functions preserve alarm state until the input returns normal.

Aplicaciones típicas

Salas de producción farmacéuticaBiocontainment facilitiesMedical cleanroom campusesSemiconductor utility monitoring

Parámetros técnicos

Typical construction values for a centralized cleanroom alarm annunciator cabinet are listed below.

Materiales CorePowder-coated steel enclosure with FR-4 annunciator boards, copper relay contacts and industrial touchscreen
Panel de espesor180-350mm de profundidad del gabinete
Ancho efectivo500-1000 mm panel width
Longitud máximaUp to 1800 mm panel height
Acero frente a espesorPaneles de acero recubiertos de polvo de 1,2-1,8mm
Densidad Core7800-8050 kg/m³ para componentes de cerramiento de acero
Conductividad térmica45-60 W/(m · K) para los paneles estructurales de acero
Superficie acabadaLight-gray powder coating with color HMI, red beacon and labeled silence-reset controls
Tipo conjuntoGasketed cabinet with pluggable alarm inputs, isolated relay outputs and network gateway
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Touchscreen or LED annunciatorFirst-out alarm logicSMS and email gatewayRedundant power supply

Planning a Cleanroom Central Alarm System specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.