Z Sistema de alarme central para sala limpa
- Priority-Based Annunciation
- First-Out Event Capture
- Zone Alarm Mapping
- Remote Notification Outputs
Introdução do produto
The cleanroom central alarm system receives dry contacts, analog alarm states and network events from environmental instruments and supporting equipment. A color touchscreen and physical audible-visual devices distinguish critical alarms from warnings and maintenance notices. First-out sequencing identifies the initiating event before secondary conditions appear, while acknowledgement, silence and reset remain separate operator actions. Local alarm panels can be distributed by suite and connected to a central workstation without replacing the independent alarm functions at each room.
Características-chave
Distinct colors and sound patterns separate critical, warning and advisory priorities.
Zone maps direct responders to the affected room, airlock, utility or equipment item.
Isolated relay and network outputs route selected alarms to BMS, EMS or remote dialers.
Soluções para sua aplicação
A central alarm system must make the first actionable condition obvious without suppressing local room-level warnings.
Aplicações típicas
Parâmetros técnicos
Typical construction values for a centralized cleanroom alarm annunciator cabinet are listed below.
| Material principal | Powder-coated steel enclosure with FR-4 annunciator boards, copper relay contacts and industrial touchscreen |
|---|---|
| Painel de espessura | 180-350mm profundidade do armário |
| Largura efetiva | 500-1000 mm panel width |
| Comprimento máximo | Up to 1800 mm panel height |
| Aço enfrentando espessura | Painéis de aço pó-revestidos de 1.2-1.8mm |
| Densidade Core | 7800-8050 kg/m³ para componentes de invólucro de aço |
| Condutividade térmica | 45-60 W/(m·K) for steel structural panels |
| Superfície acabado | Light-gray powder coating with color HMI, red beacon and labeled silence-reset controls |
| Tipo conjunto | Gasketed cabinet with pluggable alarm inputs, isolated relay outputs and network gateway |
| Customização | Disponível com base na aplicação pretendida e no ambiente operacional. |
Opções disponíveis
Planning a Cleanroom Central Alarm System specification?
Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Inglês
Portuguêsatual
Espanhol
Língua malaia
Língua indonésia
Alemão
Língua turca
Vietnã
Francês
Língua russa
Língua árabe
Tailandês
Japonês
Coreano