클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
/ 제품 / Cleanroom Air Filters / Exhaust HEPA Filter Housing Standard Side-Access
STJH-EXHAUST-HEPA-HOUSING-STANDARD

Exhaust HEPA Filter Housing Standard Side-Access

A dual-access gasket-seal cabinet for general laboratory and clean-process exhaust without contained BIBO changing.
  • Either-side service
  • 14-gauge galvanized cabinet
  • Optional 2 in prefilter
견적 요청 제품 찾아보기

상품 소개

This standard exhaust housing uses a 14-gauge galvanized cabinet, gasket-seal HEPA track and access from either side. An optional nominal 2 in prefilter protects the final element, and the family pressure capability reaches plus or minus 8 in. w.g. Unlike the BIBO version, this model is intended for exhaust streams whose hazard assessment permits conventional side-door filter removal.

주요 기능

General exhaust construction

The weather-resistant galvanized enclosure supports ducted final filtration without the added bagging system.

Flexible maintenance access

Doors on both sides allow filter withdrawal from the clear mechanical-room aisle.

Final-filter protection

A shallow prefilter option reduces coarse dust accumulation on the exhaust HEPA.

기술 매개변수

Housing Material14-gauge galvanized steel
AccessEither side
Filter TypeGasket-seal HEPA
Prefilter Track2 in nominal optional
Family Pressure Capability±8 in. w.g.
Change MethodConventional side-door removal
Cabinet DutyWeather-resistant exhaust housing
Filter ClampingMechanical gasket compression
InstallationNon-containment ducted exhaust
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

Applications

For general laboratory, medical and clean-process exhaust systems where HEPA filtration is required but the risk assessment does not require a contained change bag.

Solutions for Your Application

A hazardous exhaust stream is assigned to a standard open-change cabinet.Complete the exposure assessment first and select the BIBO containment model whenever filter removal could release unacceptable contaminants.
Outdoor placement accelerates corrosion at cut edges and fasteners.Specify weather detailing, inspect coatings and joints, and choose stainless construction where the ambient environment is aggressive.

사용 가능한 옵션

Confirm hazard classification, cabinet material, HEPA depth, gasket side, prefilter, access side, weather protection, test ports and duct flanges.

Planning a Exhaust HEPA Filter Housing Standard Side-Access specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat