موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
الرئيسية / المنتجات / Cleanroom Air Filters / Exhaust HEPA Filter Housing Standard Side-Access
STJH-EXHAUST-HEPA-HOUSING-STANDARD

Exhaust HEPA Filter Housing Standard Side-Access

A dual-access gasket-seal cabinet for general laboratory and clean-process exhaust without contained BIBO changing.
  • Either-side service
  • 14-gauge galvanized cabinet
  • Optional 2 in prefilter
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This standard exhaust housing uses a 14-gauge galvanized cabinet, gasket-seal HEPA track and access from either side. An optional nominal 2 in prefilter protects the final element, and the family pressure capability reaches plus or minus 8 in. w.g. Unlike the BIBO version, this model is intended for exhaust streams whose hazard assessment permits conventional side-door filter removal.

الخصائص الرئيسية

General exhaust construction

The weather-resistant galvanized enclosure supports ducted final filtration without the added bagging system.

Flexible maintenance access

Doors on both sides allow filter withdrawal from the clear mechanical-room aisle.

Final-filter protection

A shallow prefilter option reduces coarse dust accumulation on the exhaust HEPA.

المعلمات الفنية

Housing Material14-gauge galvanized steel
AccessEither side
Filter TypeGasket-seal HEPA
Prefilter Track2 in nominal optional
Family Pressure Capability±8 in. w.g.
Change MethodConventional side-door removal
Cabinet DutyWeather-resistant exhaust housing
Filter ClampingMechanical gasket compression
InstallationNon-containment ducted exhaust
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

For general laboratory, medical and clean-process exhaust systems where HEPA filtration is required but the risk assessment does not require a contained change bag.

Solutions for Your Application

A hazardous exhaust stream is assigned to a standard open-change cabinet.Complete the exposure assessment first and select the BIBO containment model whenever filter removal could release unacceptable contaminants.
Outdoor placement accelerates corrosion at cut edges and fasteners.Specify weather detailing, inspect coatings and joints, and choose stainless construction where the ambient environment is aggressive.

الخيارات المتاحة

Confirm hazard classification, cabinet material, HEPA depth, gasket side, prefilter, access side, weather protection, test ports and duct flanges.

Planning a Exhaust HEPA Filter Housing Standard Side-Access specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا