클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
/ 제품 / Containment & Biosafety Equipment / Compounding Isolator 1200 mm Negative-Pressure Recirculating
STJH-COMPOUNDING-ISOLATOR-1200-NEG-RECIRC

Compounding Isolator 1200 mm Negative-Pressure Recirculating

A negative-pressure recirculating compounding isolator for sterile hazardous drugs where containment and lower external exhaust demand are both needed.
  • Negative-pressure recirculation
  • Hazardous-drug containment
  • More-negative interchange
견적 요청 제품 찾아보기

상품 소개

Unlike the positive-pressure model, this enclosure uses a negative pressure arrangement for hazardous-drug containment. The interchange is maintained more negative than the main chamber, while filtered air recirculation reduces the external exhaust requirement compared with a total-exhaust isolator.

주요 기능

Containment-oriented cascade

The pressure relationship directs leakage inward, with the interchange maintained below the work chamber.

Recirculating work-zone air

HEPA-filtered recirculation supports ISO Class 5 conditions without exhausting the entire chamber flow.

Transparent glove barrier

A polycarbonate glove window provides process visibility while separating the operator from the preparation.

기술 매개변수

Nominal Width1.2 m
Work Zone895 x 591 x 695 mm
Pressure ModeNegative-pressure recirculating
Interchange PressureMore negative than the main work chamber
Air Changes20 per minute
Air CleanlinessISO Class 5 HEPA-filtered work zone
ConstructionStainless steel enclosure
Glove WindowPolycarbonate barrier panel
Intended CompoundsSterile hazardous drugs
사용자 정의Exhaust interface, interchange side and work-zone services can be tailored to the hazardous compounding process.

Applications

Sterile hazardous-drug preparation in pharmacies that need negative-pressure containment while limiting the volume sent to facility exhaust.

Solutions for Your Application

Positive pressure is unsuitable for a hazardous drug preparation.Use the negative recirculating model to establish an inward pressure direction around the contained process.
A total-exhaust cabinet would exceed the available air-handling capacity.Apply the recirculating architecture after confirming that it suits the drug and facility control strategy.

사용 가능한 옵션

Interchange orientation, base stand, work-surface accessories and facility exhaust connection can be selected for the pharmacy layout.

Planning a Compounding Isolator 1200 mm Negative-Pressure Recirculating specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat

제품

뉴스

회사 소개

문의하기