Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Laman Utama / Produk / Containment & Biosafety Equipment / Compounding Isolator 1200 mm Negative-Pressure Recirculating
STJH-COMPOUNDING-ISOLATOR-1200-NEG-RECIRC

Compounding Isolator 1200 mm Negative-Pressure Recirculating

A negative-pressure recirculating compounding isolator for sterile hazardous drugs where containment and lower external exhaust demand are both needed.
  • Negative-pressure recirculation
  • Hazardous-drug containment
  • More-negative interchange
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

Unlike the positive-pressure model, this enclosure uses a negative pressure arrangement for hazardous-drug containment. The interchange is maintained more negative than the main chamber, while filtered air recirculation reduces the external exhaust requirement compared with a total-exhaust isolator.

Ciri-ciri Utama

Containment-oriented cascade

The pressure relationship directs leakage inward, with the interchange maintained below the work chamber.

Recirculating work-zone air

HEPA-filtered recirculation supports ISO Class 5 conditions without exhausting the entire chamber flow.

Transparent glove barrier

A polycarbonate glove window provides process visibility while separating the operator from the preparation.

Parameter teknikal

Nominal Width1.2 m
Work Zone895 x 591 x 695 mm
Pressure ModeNegative-pressure recirculating
Interchange PressureMore negative than the main work chamber
Air Changes20 per minute
Air CleanlinessISO Class 5 HEPA-filtered work zone
ConstructionStainless steel enclosure
Glove WindowPolycarbonate barrier panel
Intended CompoundsSterile hazardous drugs
PenyesuaianExhaust interface, interchange side and work-zone services can be tailored to the hazardous compounding process.

Applications

Sterile hazardous-drug preparation in pharmacies that need negative-pressure containment while limiting the volume sent to facility exhaust.

Solutions for Your Application

Positive pressure is unsuitable for a hazardous drug preparation.Use the negative recirculating model to establish an inward pressure direction around the contained process.
A total-exhaust cabinet would exceed the available air-handling capacity.Apply the recirculating architecture after confirming that it suits the drug and facility control strategy.

Pilihan yang boleh didapati

Interchange orientation, base stand, work-surface accessories and facility exhaust connection can be selected for the pharmacy layout.

Planning a Compounding Isolator 1200 mm Negative-Pressure Recirculating specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami