클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
홈 / 제품 / 클린룸 장비 / Refrigerated Cleanroom Pass Box
인력 및 재료 오염 제거 장비

냉장실 패스 박스 (Cleanroom Pass Box)

An actively refrigerated, interlocked pass box for short handovers of compatible temperature-sensitive materials between controlled rooms.
  • Insulated Cold Chamber
  • Programmable Temperature Control
  • Condensate Drain
  • Interlocked Cold-Transfer Doors
견적 요청 제품 찾아보기

상품 소개

The refrigerated cleanroom pass box places a compact cooling system above a double-wall stainless transfer chamber. An internal fan moves conditioned air around the load, while the insulated enclosure and gasketed doors limit heat gain from the adjoining rooms. A temperature sensor and controller operate the refrigeration cycle, and a separate drain route carries evaporator condensate away from the wall opening.

주요 기능

Active cooling supports a chilled handover rather than relying on an uncooled metal cabinet.

A digital display makes chamber-air temperature visible to the operator.

One-door-at-a-time access avoids a direct opening between the two rooms.

Removable racks expose the interior for wipe-down and load arrangement.

An external refrigeration section keeps service components outside the usable transfer volume.

응용 프로그램 솔루션

A chilled transfer depends on both the refrigeration arrangement and the way each load is handed over.

A pre-chilled sample waits in a warm transfer opening.Use a refrigerated chamber and a short, coordinated handover to reduce exposure while the receiving side is prepared.
Warm, heavy loads consume the available cooling capacity.Transfer preconditioned materials in load sizes suited to the cooling configuration instead of using the pass box to cool bulk stock.
Condensate wets the wall interface or collects below the chamber.Route the evaporator drain to a suitable collection or drainage point and keep that route accessible for cleaning.
Tightly packed containers obstruct the conditioned-air path.Choose an open rack arrangement and leave space around the fan outlet and return path rather than filling every shelf edge.

일반적인 응용 프로그램

Short handovers of chilled laboratory samplesCompatible reagents and media entering biotechnology roomsTemperature-sensitive packaged components in preparation areasPharmacy cleanroom material-transfer routes

기술 매개변수

These are common selectable reference configurations for compressor-cooled pass boxes, not measured STjh performance. The usual build combines an insulated stainless chamber, active refrigeration, air circulation, temperature control, condensate drainage and interlocked doors. The selected cooling range depends on the complete refrigeration configuration.

양도 의무Short-duration refrigerated material transfer between controlled rooms
챔버 재질304 stainless steel; 316L stainless steel available as an option
Reference Internal SizeApproximately 600 × 600 × 600 mm (W × D × H); custom sizes available
Temperature Options+2 to +8 °C refrigerated configuration; +12 to +16 °C moderate-cooling configuration
Refrigeration SystemCompressor-based closed-loop cooling with fan-circulated chamber air
문 배열Two gasketed access doors with electronic interlocking
온도 조절Digital chamber-temperature display and programmable setpoint control
Condensate ManagementEvaporator drain connection routed through the service or wall interface
선반Removable stainless shelf or rack with clearance for air circulation
전원 공급 장치230 V, 50 Hz reference configuration
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Active cooling and temperature control belong to the refrigerated configuration. The following choices adapt its construction and monitoring to the transfer task.

316L stainless chamber interiorAlternate internal dimensions and door orientationRemovable stainless shelf-rack arrangementsTemperature alarm with remote contactAlternative chilled or moderate-cooling configuration

Selection and Installation

Select the cooling configuration using the material's required temperature band, incoming temperature, package size, load mass and transfer frequency. Bring compatible materials to the intended condition before loading: this pass box is a short-transfer station, not a long-term refrigerator or a rapid pull-down freezer. Chamber-air readings do not replace the handling requirements for the material inside its packaging.

Allow ventilation and service clearance around the refrigeration module, provide a suitable condensate route, and support the insulated cabinet independently of a light wall panel. Leave space around racks and containers for the circulation path. If the load is bulky but does not require cooling, consider the 대형 클린룸 재료 전달 챔버 for an ambient-temperature equipment route.

Planning a Refrigerated Cleanroom Pass Box specification?