Kotak Pas Cleanroom yang disejukkan
- Dewan sejuk bertebat
- Kawalan Suhu Boleh Atur Cara
- Condensate Drain
- Pintu Pemindahan Sejuk Bersambung
Pengenalan Produk
The refrigerated cleanroom pass box places a compact cooling system above a double-wall stainless transfer chamber. An internal fan moves conditioned air around the load, while the insulated enclosure and gasketed doors limit heat gain from the adjoining rooms. A temperature sensor and controller operate the refrigeration cycle, and a separate drain route carries evaporator condensate away from the wall opening.
Ciri-ciri Utama
A digital display makes chamber-air temperature visible to the operator.
One-door-at-a-time access avoids a direct opening between the two rooms.
Removable racks expose the interior for wipe-down and load arrangement.
An external refrigeration section keeps service components outside the usable transfer volume.
Penyelesaian untuk permohonan anda
A chilled transfer depends on both the refrigeration arrangement and the way each load is handed over.
Permohonan yang biasa
Parameter teknikal
These are common selectable reference configurations for compressor-cooled pass boxes, not measured STjh performance. The usual build combines an insulated stainless chamber, active refrigeration, air circulation, temperature control, condensate drainage and interlocked doors. The selected cooling range depends on the complete refrigeration configuration.
| Cukai Pindah Milik | Short-duration refrigerated material transfer between controlled rooms |
|---|---|
| Bahan Ruang | 304 stainless steel; 316L stainless steel available as an option |
| Reference Internal Size | Approximately 600 × 600 × 600 mm (W × D × H); custom sizes available |
| Temperature Options | +2 to +8 °C refrigerated configuration; +12 to +16 °C moderate-cooling configuration |
| Refrigeration System | Compressor-based closed-loop cooling with fan-circulated chamber air |
| Susunan Pintu | Two gasketed access doors with electronic interlocking |
| Kawalan Suhu | Digital chamber-temperature display and programmable setpoint control |
| Condensate Management | Evaporator drain connection routed through the service or wall interface |
| Rak | Removable stainless shelf or rack with clearance for air circulation |
| Bekalan Kuasa | 230 V, 50 Hz reference configuration |
| Penyesuaian | Boleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi. |
Pilihan yang boleh didapati
Active cooling and temperature control belong to the refrigerated configuration. The following choices adapt its construction and monitoring to the transfer task.
Selection and Installation
Select the cooling configuration using the material's required temperature band, incoming temperature, package size, load mass and transfer frequency. Bring compatible materials to the intended condition before loading: this pass box is a short-transfer station, not a long-term refrigerator or a rapid pull-down freezer. Chamber-air readings do not replace the handling requirements for the material inside its packaging.
Allow ventilation and service clearance around the refrigeration module, provide a suitable condensate route, and support the insulated cabinet independently of a light wall panel. Leave space around racks and containers for the circulation path. If the load is bulky but does not require cooling, consider the Dewan Pemindahan Bahan Bilik Bersih Besar for an ambient-temperature equipment route.
Merancang spesifikasi kotak lulus Cleanroom yang disimpan dalam peti sejuk?
Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Bahasa Inggeris
Bahasa Portugis: Bahasa Portugis: Bahasa Portugis
Bahasa Sepanyol: Bahasa Sepanyol: Bahasa Sepanyol
Bahasa Melayu (Bahasa Melayu)Semasa
Bahasa Indonesia: Bahasa Indonesia
Bahasa Jerman
Bahasa Turki: Bahasa Turki
Bahasa Vietnam (Bahasa Melayu)
Bahasa Perancis
Bahasa Rusia
Bahasa Arab (Bahasa Melayu)
Bahasa Melayu (Bahasa Melayu)
Bahasa Jepun
Bahasa Korea (Bahasa Melayu)