مبردة غرفة نظيفة تمرير مربع
- غرفة باردة معزولة
- التحكم في درجة الحرارة للبرمجة
- Condensate Drain
- أبواب نقل باردة متشابكة
مقدمة المنتج
The refrigerated cleanroom pass box places a compact cooling system above a double-wall stainless transfer chamber. An internal fan moves conditioned air around the load, while the insulated enclosure and gasketed doors limit heat gain from the adjoining rooms. A temperature sensor and controller operate the refrigeration cycle, and a separate drain route carries evaporator condensate away from the wall opening.
الخصائص الرئيسية
A digital display makes chamber-air temperature visible to the operator.
One-door-at-a-time access avoids a direct opening between the two rooms.
Removable racks expose the interior for wipe-down and load arrangement.
An external refrigeration section keeps service components outside the usable transfer volume.
حلول للتطبيق الخاص بك
A chilled transfer depends on both the refrigeration arrangement and the way each load is handed over.
تطبيقات نموذجية
المعلمات الفنية
These are common selectable reference configurations for compressor-cooled pass boxes, not measured STjh performance. The usual build combines an insulated stainless chamber, active refrigeration, air circulation, temperature control, condensate drainage and interlocked doors. The selected cooling range depends on the complete refrigeration configuration.
| Transfer Duty | Short-duration refrigerated material transfer between controlled rooms |
|---|---|
| مواد الغرفة | 304 stainless steel; 316L stainless steel available as an option |
| Reference Internal Size | Approximately 600 × 600 × 600 mm (W × D × H); custom sizes available |
| Temperature Options | +2 to +8 °C refrigerated configuration; +12 to +16 °C moderate-cooling configuration |
| Refrigeration System | Compressor-based closed-loop cooling with fan-circulated chamber air |
| ترتيب الباب | Two gasketed access doors with electronic interlocking |
| التحكم في درجة الحرارة | Digital chamber-temperature display and programmable setpoint control |
| Condensate Management | Evaporator drain connection routed through the service or wall interface |
| رفوف | Removable stainless shelf or rack with clearance for air circulation |
| مزود طاقة | 230 V, 50 Hz reference configuration |
| التخصيص | متوفر على أساس التطبيق المقصود وبيئة التشغيل. |
الخيارات المتاحة
Active cooling and temperature control belong to the refrigerated configuration. The following choices adapt its construction and monitoring to the transfer task.
Selection and Installation
Select the cooling configuration using the material's required temperature band, incoming temperature, package size, load mass and transfer frequency. Bring compatible materials to the intended condition before loading: this pass box is a short-transfer station, not a long-term refrigerator or a rapid pull-down freezer. Chamber-air readings do not replace the handling requirements for the material inside its packaging.
Allow ventilation and service clearance around the refrigeration module, provide a suitable condensate route, and support the insulated cabinet independently of a light wall panel. Leave space around racks and containers for the circulation path. If the load is bulky but does not require cooling, consider the غرفة نقل المواد الغرف النظيفة الكبيرة for an ambient-temperature equipment route.
تخطيط مواصفات صندوق تمرير غرف الأبحاث المبردة ؟
أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.