クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
ホーム / 製品 / クリーンルーム機器 / VHP Pass Box 600 mm
STJH-VHP-PASS-BOX-600

VHP Pass Box 600 mm

A compact VHP transfer chamber for tools, bags and small thermolabile aseptic loads.
  • 600 mm 316 stainless chamber
  • H14 filtered process airflow
  • Compact aseptic transfer capacity
見積もりリクエスト 製品案内

商品紹介

The 600 mm VHP pass box is the smallest chamber in this family, using a 600 x 600 x 600 mm 316 stainless interior within a 1200 x 660 x 2000 mm service enclosure. H14 filtration supports the controlled airflow path through conditioning, vapor exposure and aeration. Published family cycle time is 90–150 minutes and the release target is below 1 ppm residue, but both values require confirmation for the actual load and room interface.

主要な特徴

Small-load cycle efficiency

The compact volume avoids conditioning a large empty chamber when routine loads are tools, bags or small component kits.

Corrosion-resistant interior

316 stainless construction suits repeated exposure and cleaning within the vapor treatment zone.

Monitored aeration endpoint

The cycle can hold clean-side release until the configured low-residue condition is reached.

技術的なパラメータ

Internal Chamber600 x 600 x 600 mm
External Dimensions1200 x 660 x 2000 mm
Chamber Material316 stainless steel
Final FilterH14
Source-Family Cycle Time90–150 min
Residue Release TargetBelow 1 ppm, subject to cycle validation
Process StagesConditioning, VHP exposure and aeration
Load TypeTools, bags and compact aseptic loads
InstallationIntegrated wall transfer system
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

Applications

For small sterile material loads entering pharmaceutical, biotechnology and aseptic processing areas without high-temperature treatment. Product compatibility, hydrogen-peroxide absorption and aeration time must be tested with the actual load rather than inferred from empty-chamber performance.

Solutions for Your Application

A large VHP chamber wastes cycle time and vapor on small daily loads.Use the 600 mm chamber to match the treatment volume to compact tools and bagged components.
Absorbent materials may retain peroxide after the nominal cycle ends.Develop the cycle with the worst-case load and release only after the installed concentration monitor reaches the approved endpoint.

利用可能なオプション

Define VHP generator interface, concentration sensing, door orientation, cycle recipe access, printer or data export and emergency aeration logic. Final cycle performance depends on load material and packing density.

Planning a VHP Pass Box 600 mm specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat

ホーム

製品

ニュース

会社概要

お問い合わせ