Permanganate-Impregnated Media Filter 305 × 610 × 305 mm

A deep disposable cassette carrying one cubic foot of oxidizing media for broad corrosion and odor control.
  • One cubic foot media charge
  • 3 in packed bed
  • Disposable 12 x 24 module
見積もりリクエスト 製品案内

商品紹介

This nominal 12 x 24 x 12 in cassette uses a 3 in packed bed and a full cubic foot of engineered permanganate-impregnated media. The deep bed favors contaminant capacity and contact time over minimal resistance, making the module appropriate for purpose-designed molecular-filter sections rather than shallow retrofits. It can address selected corrosive and odorous gases, but the final media blend must match the measured gas mixture and operating humidity.

主要な特徴

Deep reaction bed

A three-inch media path provides meaningful contact time for chemisorption and oxidation.

Factory-contained cassette

The disposable module keeps granular media enclosed during installation and removal.

Blend flexibility

Permanganate media can be combined with complementary adsorbents for the documented contaminant mix.

技術的なパラメータ

Nominal Dimensions305 x 610 x 305 mm
Media Volume1 ft3
Packed Bed Depth3 in
Media TypePermanganate-impregnated engineered media blend
ConstructionFactory-filled disposable cassette
Maximum Operating Temperature52 C
Target DutyCorrosion, odor and mixed-gas control
InstallationDedicated molecular-filter rack
Change CriterionMedia analysis or downstream gas trend
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

Applications

Suitable for commercial and industrial air handlers, control rooms and process facilities that require a deep chemical bed for corrosive or odorous gaseous contaminants.

Solutions for Your Application

The deep granular bed adds more resistance than a shallow retrofit rack can tolerate.Review the fan curve and use sufficient parallel face area; choose the low-drop 152 mm-high module when static pressure is the primary constraint.
A single oxidizing medium does not cover every compound in a mixed-gas stream.Use site sampling to select a permanganate and adsorbent blend matched to the identified acids, sulfur gases or VOCs.

利用可能なオプション

Confirm contaminant species, media blend, bank airflow, rack orientation, upstream filtration, sampling interval and sealed change procedure.

Planning a Permanganate-Impregnated Media Filter 305 × 610 × 305 mm specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。