クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
ホーム / 製品 / クリーンルーム機器 / Fan Filter Unit 24 × 48 in High-Airflow
STJH-HIGH-AIRFLOW-FFU-24X48-950CFM

Fan Filter Unit 24 × 48 in High-Airflow

The highest-volume standard high-airflow FFU in this group, rated up to 950 CFM.
  • 200-950 CFM operating range
  • 600 x 1200 mm full-length footprint
  • 650 CFM reference airflow at 90 FPM
見積もりリクエスト 製品案内

商品紹介

This full-length 24 x 48 in model provides the largest standard airflow range in the accepted high-flow family, from 200 to 950 CFM. It supplies 650 CFM at a 90 FPM reference point and carries a 66 lb housing across a 600 x 1200 x 364 mm envelope. The model suits broad ceiling zones where one module should cover more area and deliver more volume than the 24 x 36 in format.

主要な特徴

Maximum standard airflow

The 950 CFM upper limit provides the greatest volume in the non-RSR high-airflow group.

Broad filter-face coverage

A two-by-four-foot cabinet can reduce module count across large production ceiling zones.

Adjustable ECM output

The ECM can be commissioned below maximum duty to match the installed filter and room return system.

技術的なパラメータ

Nominal Module Size2 x 4 ft
External Dimensions600 x 1200 x 364 mm
Airflow Range200-950 CFM
Reference Airflow650 CFM at 90 FPM
Maximum-Airflow Power250 W
Reference Sound Level52 dBA at 90 FPM
Motor TypeECM
Unit Weight66 lb
InstallationFull-perimeter supported 2 x 4 ft ceiling mounting
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

Applications

Suitable for high-coverage electronics, pharmaceutical and precision-manufacturing ceilings, especially where the airflow plan favors fewer large modules. The 950 CFM capability must be coordinated with room returns, ceiling support and acceptable sound levels.

Solutions for Your Application

Too many medium FFUs add controls and joints to a large cleanroom ceiling.Use the 2 x 4 ft module to consolidate coverage where the structural grid and air balance permit.
Operating at maximum volume may create more airflow or noise than the process needs.Commission the ECM from the 650 CFM reference duty and increase output only after verifying the room pressure and velocity profile.

利用可能なオプション

Confirm the final-filter grade, ECM control interface, voltage, housing construction and ceiling support. Select the actual airflow from the measured resistance and cleanliness requirement.

Planning a Fan Filter Unit 24 × 48 in High-Airflow specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat

ホーム

製品

ニュース

会社概要

お問い合わせ