클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
/ 제품 / 클린룸 장비 / Fan Filter Unit 24 × 48 in High-Airflow
STJH-HIGH-AIRFLOW-FFU-24X48-950CFM

Fan Filter Unit 24 × 48 in High-Airflow

The highest-volume standard high-airflow FFU in this group, rated up to 950 CFM.
  • 200-950 CFM operating range
  • 600 x 1200 mm full-length footprint
  • 650 CFM reference airflow at 90 FPM
견적 요청 제품 찾아보기

상품 소개

This full-length 24 x 48 in model provides the largest standard airflow range in the accepted high-flow family, from 200 to 950 CFM. It supplies 650 CFM at a 90 FPM reference point and carries a 66 lb housing across a 600 x 1200 x 364 mm envelope. The model suits broad ceiling zones where one module should cover more area and deliver more volume than the 24 x 36 in format.

주요 기능

Maximum standard airflow

The 950 CFM upper limit provides the greatest volume in the non-RSR high-airflow group.

Broad filter-face coverage

A two-by-four-foot cabinet can reduce module count across large production ceiling zones.

Adjustable ECM output

The ECM can be commissioned below maximum duty to match the installed filter and room return system.

기술 매개변수

Nominal Module Size2 x 4 ft
External Dimensions600 x 1200 x 364 mm
Airflow Range200-950 CFM
Reference Airflow650 CFM at 90 FPM
Maximum-Airflow Power250 W
Reference Sound Level52 dBA at 90 FPM
Motor TypeECM
Unit Weight66 lb
InstallationFull-perimeter supported 2 x 4 ft ceiling mounting
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

Applications

Suitable for high-coverage electronics, pharmaceutical and precision-manufacturing ceilings, especially where the airflow plan favors fewer large modules. The 950 CFM capability must be coordinated with room returns, ceiling support and acceptable sound levels.

Solutions for Your Application

Too many medium FFUs add controls and joints to a large cleanroom ceiling.Use the 2 x 4 ft module to consolidate coverage where the structural grid and air balance permit.
Operating at maximum volume may create more airflow or noise than the process needs.Commission the ECM from the 650 CFM reference duty and increase output only after verifying the room pressure and velocity profile.

사용 가능한 옵션

Confirm the final-filter grade, ECM control interface, voltage, housing construction and ceiling support. Select the actual airflow from the measured resistance and cleanliness requirement.

Planning a Fan Filter Unit 24 × 48 in High-Airflow specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat

제품

뉴스

회사 소개

문의하기