A two-blower hazardous-location air shower with an 88 in route for approximately three occupants.
  • 52 x 96 x 120 in cabinet
  • Two 1000 CFM blower modules
  • Approximate three-person occupancy
見積もりリクエスト 製品案内

商品紹介

The 96 in deep version expands the internal path to 88 in and adds a second blower module for an approximate three-person load. Stainless construction and pneumatic access remain central to the hazardous-location architecture. Compared with the 44 in model, it offers group throughput and longer exposure, while avoiding the floor and electrical demand of the 144 in tunnel.

主要な特徴

Small-group capacity

The 88 in chamber depth accommodates approximately three personnel in one controlled cycle.

Dual air-system coverage

Two blower sections distribute shower airflow over the longer occupied path.

Classified-entry controls

Pneumatic operation supports facility designs that restrict ordinary electrical devices at the doorway.

技術的なパラメータ

External Envelope52 W x 96 D x 120 H in
Internal Chamber35.5 W x 88 D x 83 H in
Nominal OccupancyApproximately 3 people
Number of Blowers2
Blower Performance1000 CFM at 4 in static pressure per cited blower basis
Hazard SchemeClass I, Division 2
Door Clearance36 W x 81 H in
Access MethodPneumatic push-button operation
ConstructionStainless steel with stainless door frames
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

Applications

Suitable for small-team entry to classified clean production in chemical processing, pharmaceutical handling and aerospace finishing. User spacing, purge logic and the room's hazardous classification should be resolved before the two-blower system is specified.

Solutions for Your Application

Single-person cycling creates unacceptable queues at a hazardous cleanroom entrance.Use the 88 in chamber to accommodate an approximately three-person group within one controlled sequence.
The longer chamber may not have enough maintenance clearance around both blowers.Reserve access to each air module and its filter path along the 96 in body.

利用可能なオプション

Select electrical and pneumatic utilities, door operation, filter monitoring, stainless finish and cycle logic for the classified space. Confirm the hazard group and ventilation design with the responsible safety engineer.

Planning a Explosion-Resistant Air Shower 52 × 96 in specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。