موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
الرئيسية / المنتجات / معدات الغرف النظيفة / Explosion-Resistant Air Shower 52 × 96 in
STJH-EXPLOSION-RESISTANT-AIR-SHOWER-52X96

Explosion-Resistant Air Shower 52 × 96 in

A two-blower hazardous-location air shower with an 88 in route for approximately three occupants.
  • 52 x 96 x 120 in cabinet
  • Two 1000 CFM blower modules
  • Approximate three-person occupancy
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The 96 in deep version expands the internal path to 88 in and adds a second blower module for an approximate three-person load. Stainless construction and pneumatic access remain central to the hazardous-location architecture. Compared with the 44 in model, it offers group throughput and longer exposure, while avoiding the floor and electrical demand of the 144 in tunnel.

الخصائص الرئيسية

Small-group capacity

The 88 in chamber depth accommodates approximately three personnel in one controlled cycle.

Dual air-system coverage

Two blower sections distribute shower airflow over the longer occupied path.

Classified-entry controls

Pneumatic operation supports facility designs that restrict ordinary electrical devices at the doorway.

المعلمات الفنية

External Envelope52 W x 96 D x 120 H in
Internal Chamber35.5 W x 88 D x 83 H in
Nominal OccupancyApproximately 3 people
Number of Blowers2
Blower Performance1000 CFM at 4 in static pressure per cited blower basis
Hazard SchemeClass I, Division 2
Door Clearance36 W x 81 H in
Access MethodPneumatic push-button operation
ConstructionStainless steel with stainless door frames
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

Suitable for small-team entry to classified clean production in chemical processing, pharmaceutical handling and aerospace finishing. User spacing, purge logic and the room's hazardous classification should be resolved before the two-blower system is specified.

Solutions for Your Application

Single-person cycling creates unacceptable queues at a hazardous cleanroom entrance.Use the 88 in chamber to accommodate an approximately three-person group within one controlled sequence.
The longer chamber may not have enough maintenance clearance around both blowers.Reserve access to each air module and its filter path along the 96 in body.

الخيارات المتاحة

Select electrical and pneumatic utilities, door operation, filter monitoring, stainless finish and cycle logic for the classified space. Confirm the hazard group and ventilation design with the responsible safety engineer.

Planning a Explosion-Resistant Air Shower 52 × 96 in specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat