クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
ホーム / 製品情報 / クリーンルーム機器 /クリーンルームHEPAターミナルハウジング
FFU およびターミナル空気浄化装置

クリーンルーム HEPA ターミナルハウジング

A reusable duct-connected housing for a replaceable final filter, with access from the room side and no internal fan.
  • Fanless Ducted Housing
  • Replaceable Final Filter
  • Room-Side Service Access
  • Top or Side Inlet Options
見積もりリクエスト 製品案内

商品紹介

The cleanroom HEPA terminal housing provides the casing and retaining interface between a supply duct and a replaceable final-filter panel. A welded plenum directs incoming air to the filter seat, while the removable front gives access to the filter without taking down the duct connection. Top and side inlets accommodate different ceiling layouts. This housing relies on the building's air-supply system; it contains no fan and is not a self-powered air cleaner.

主要な特徴

The casing can remain connected to the duct when the final filter is replaced.

A defined filter seat separates media replacement from ceiling-perimeter sealing.

Inlet-position choices help avoid beams and other services above the ceiling.

A removable diffuser exposes the service opening from the controlled-room side.

アプリケーションのソリューション

The filter-to-housing interface deserves as much attention as the filter media itself.

A replacement panel fits the opening but not the sealing interface.Match frame depth, gasket location and retaining geometry instead of ordering by face size alone.
The existing duct route leaves little space above the ceiling.Compare top and side entry layouts, including collar length, insulation and the connecting bend.
Filter service would otherwise disturb the ceiling void.Use the room-side opening and provide enough clearance to handle the panel without contacting its media.
Air bypasses the filter at the retaining frame.Inspect the seat, apply the specified retention method and check the installed perimeter after assembly.

典型的な用途

製薬クリーンルームの天井Hospital isolation and procedure roomsバイオテクノロジー研究所Food and beverage controlled areasDucted microelectronics clean zones

技術的なパラメータ

Common reference configuration choices for filter sizes, duct connections and room-side access.

Air SourceDucted central air supply; no internal fan
Common Filter Face Sizes610 x 305 mm or 610 x 610 mm nominal panel dimensions
Common Filter Depth Options78 mm or 150 mm, with a matching seat and housing
Common Circular Duct Sizes200 mm, 250 mm or 315 mm nominal diameter
Common Housing MaterialsPowder-coated steel or stainless steel
Inlet ArrangementTop circular, side circular or side rectangular connection
Filter-Seal OptionsCompression gasket or matching gel/knife-edge interface
フィルターアクセスRoom-side removal through a detachable diffuser opening
拡散器のオプションPerforated face or an alternative matched distribution plate
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

トップまたはサイドダクト接続Dry-gasket or gel-seal filter seatMatched HEPA or ULPA panelBalancing damper and test connections

Housing, final filter, diffuser and accessories can be specified as a matched supply package; identify the included components when requesting a quotation.

Selection and Installation

Match the replacement filter to its seat

Specify the panel's width, length, depth, seal location and frame profile together. Nominal filter size is not the ceiling cut-out or the housing outside dimension. A dry-gasket panel and a gel-channel panel require the corresponding retaining interface; equal face dimensions do not make them interchangeable.

Allow for the complete supply-air resistance

The upstream air-handling system supplies the pressure required for the duct, inlet fitting, damper and loaded final filter. Select the terminal at the required air volume and filter resistance rather than assigning it a motor power or an independent fan curve. If local fan assistance is required, compare the fan-powered HEPA module.

Plan replacement without removing the duct

Check the diffuser opening, filter withdrawal space and the handling route below the ceiling. Support the housing from the intended structural points and avoid using the supply duct as its hanger. Provide access to the selected pressure and aerosol connections so the installed filter and its perimeter can be checked after replacement.

Choose the supply configuration

The common dimensions above are reference options for selection. Match the actual casing, collar orientation, final-filter class and front plate in the supplied assembly. For a coordinated terminal package with balancing and testing components, see the integrated clean-air supply module.

クリーンルームHEPAターミナルハウジング仕様を計画していますか?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat

ホーム

製品情報

ニュース

会社概要

お問い合わせ