Sterility Test Isolator 1200 mm Two-Glove

The compact member of the sterility-test family, combining a 1200 mm two-glove process chamber with lower standard airflow demand.
  • 1200 mm internal chamber
  • Two glove positions
  • Compact airflow requirement
Permintaan untuk kutipan Browse Produk

Perkenalan produk

A 1200 x 540 x 700 mm internal chamber provides a defined station for limited sample volumes and an integrated sterility-test pump. The two glove positions suit a focused workflow, while the compact chamber requires less process air than the 1600 and 2000 mm versions.

Fitur utama:

Focused testing layout

Two glove ports place essential test handling within one compact operator reach zone.

High-grade supply filtration

U15 supply filtration supports the clean process environment, with H14 filtration on the exhaust path.

Selectable air architecture

The chamber can be arranged for total exhaust or a lower-volume recirculating operating mode.

Parameter teknis

Internal Process Chamber1200 x 540 x 700 mm
External Process-Chamber Envelope1504 x 881 x 2430 mm
Glove Ports2
Supply FilterU15, nominal 99.9995% at MPPS
Exhaust FilterH14, nominal 99.995% at MPPS
Total-Exhaust Airflow1021 m³/h
Recirculating Airflow510 m³/h
Typical Process EquipmentIntegrated sterility-test pump
Relative Family SizeSmallest standard chamber in the retained range
Customization (Kustomisasi)Transfer chamber, pump arrangement and utility connections can be tailored to the sterility-test method.

Applications

Pharmaceutical quality-control sterility testing with limited sample volume, compact equipment staging and two-glove manipulation.

Solutions for Your Application

A large isolator would add unnecessary air volume and floor space for a focused test method.Use the 1200 mm chamber when the pump, samples and consumables fit within the two-glove work pattern.
The chosen exhaust mode may not match the facility connection.Select total-exhaust or recirculating architecture after reviewing room exhaust capacity and the test materials.

Pilihan yang tersedia

Pass chambers, sterility-test pump integration, monitoring instruments and exhaust configuration can be arranged around the laboratory method.

Planning a Sterility Test Isolator 1200 mm Two-Glove specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami