Trang chủ / Sản phẩm / Containment & Biosafety Equipment / Sterility Test Isolator 1200 mm Two-Glove
STJH-STERILITY-TEST-ISOLATOR-1200-2G

Sterility Test Isolator 1200 mm Two-Glove

The compact member of the sterility-test family, combining a 1200 mm two-glove process chamber with lower standard airflow demand.
  • 1200 mm internal chamber
  • Two glove positions
  • Compact airflow requirement
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

A 1200 x 540 x 700 mm internal chamber provides a defined station for limited sample volumes and an integrated sterility-test pump. The two glove positions suit a focused workflow, while the compact chamber requires less process air than the 1600 and 2000 mm versions.

Các tính năng chính

Focused testing layout

Two glove ports place essential test handling within one compact operator reach zone.

High-grade supply filtration

U15 supply filtration supports the clean process environment, with H14 filtration on the exhaust path.

Selectable air architecture

The chamber can be arranged for total exhaust or a lower-volume recirculating operating mode.

Thông số kỹ thuật

Internal Process Chamber1200 x 540 x 700 mm
External Process-Chamber Envelope1504 x 881 x 2430 mm
Glove Ports2
Supply FilterU15, nominal 99.9995% at MPPS
Exhaust FilterH14, nominal 99.995% at MPPS
Total-Exhaust Airflow1021 m³/h
Recirculating Airflow510 m³/h
Typical Process EquipmentIntegrated sterility-test pump
Relative Family SizeSmallest standard chamber in the retained range
Tùy chỉnhTransfer chamber, pump arrangement and utility connections can be tailored to the sterility-test method.

Applications

Pharmaceutical quality-control sterility testing with limited sample volume, compact equipment staging and two-glove manipulation.

Solutions for Your Application

A large isolator would add unnecessary air volume and floor space for a focused test method.Use the 1200 mm chamber when the pump, samples and consumables fit within the two-glove work pattern.
The chosen exhaust mode may not match the facility connection.Select total-exhaust or recirculating architecture after reviewing room exhaust capacity and the test materials.

Các tùy chọn có sẵn

Pass chambers, sterility-test pump integration, monitoring instruments and exhaust configuration can be arranged around the laboratory method.

Planning a Sterility Test Isolator 1200 mm Two-Glove specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Nói chuyện với đội ngũ của chúng tôi
Email cho chúng tôi WhatsApp WeChat

Trang chủ

Sản phẩm

Tin tức

Về chúng tôi

Liên hệ