A narrow 16 x 24 in reverse-flow HEPA module for compact negative-pressure exhaust points.
  • 16 x 24 in narrow footprint
  • 2.2 ft² active filter face
  • Room-side service with dust pan
Permintaan untuk kutipan Browse Produk

Perkenalan produk

The shortest narrow reverse-flow unit uses a 15.7 x 23.63 in footprint and a 16.125 in height. Air is drawn from the controlled space through a MERV 7 prefilter and 99.99% HEPA stage, while a dust collector pan supports room-side service. Its 2.2 ft² active face is tailored to small isolation or maintenance enclosures.

Fitur utama:

Compact exhaust pickup

The short chassis fits negative-pressure ceiling positions where a conventional 2 x 2 ft unit is too wide.

Contained room-side maintenance

The collector pan and room-side access reduce reliance on an overhead service space.

Adjustable reverse flow

A variable-speed 1/4 hp PSC assembly allows the exhaust contribution to be balanced.

Parameter teknis

Product Dimensions15.7 W x 23.63 D x 16.125 H in
Active Filter Face2.2 ft²
Airflow DirectionReverse-flow negative pressure
Final FilterHEPA, 99.99% at 0.3 µm
PrefilterMERV 7
Motor and Blower1/4 hp PSC, backward-curved
Electrical120 V, 0.9 A, 105 W, single phase, 50/60 Hz
HousingPowder-coated steel with aluminium filter frame
Filter AccessRoom-side with dust collector pan
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Applications

Designed for compact isolation rooms, cleanroom renovation enclosures and localized equipment-repair containment. The 16 in width is particularly useful between congested ceiling services.

Solutions for Your Application

A standard exhaust module cannot fit the narrow ceiling opening.Use the 15.7 in wide cabinet and keep the room-side filter face accessible.
Dust may fall during filter service.Retain the integral collection pan and follow a controlled room-side removal sequence.

Pilihan yang tersedia

Choose ceiling frame, duct adapter, filter alarm, suspension hardware and control panel. Balance the variable-speed exhaust against replacement air.

Planning a Negative-Pressure HEPA Filtration Unit 16 × 24 in specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.