Trang chủ / Sản phẩm / Thiết bị phòng sạch / Negative-Pressure HEPA Filtration Unit 16 × 24 in
STJH-NEGATIVE-PRESSURE-HEPA-UNIT-16X24

Negative-Pressure HEPA Filtration Unit 16 × 24 in

A narrow 16 x 24 in reverse-flow HEPA module for compact negative-pressure exhaust points.
  • 16 x 24 in narrow footprint
  • 2.2 ft² active filter face
  • Room-side service with dust pan
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

The shortest narrow reverse-flow unit uses a 15.7 x 23.63 in footprint and a 16.125 in height. Air is drawn from the controlled space through a MERV 7 prefilter and 99.99% HEPA stage, while a dust collector pan supports room-side service. Its 2.2 ft² active face is tailored to small isolation or maintenance enclosures.

Các tính năng chính

Compact exhaust pickup

The short chassis fits negative-pressure ceiling positions where a conventional 2 x 2 ft unit is too wide.

Contained room-side maintenance

The collector pan and room-side access reduce reliance on an overhead service space.

Adjustable reverse flow

A variable-speed 1/4 hp PSC assembly allows the exhaust contribution to be balanced.

Thông số kỹ thuật

Product Dimensions15.7 W x 23.63 D x 16.125 H in
Active Filter Face2.2 ft²
Airflow DirectionReverse-flow negative pressure
Final FilterHEPA, 99.99% at 0.3 µm
PrefilterMERV 7
Motor and Blower1/4 hp PSC, backward-curved
Electrical120 V, 0.9 A, 105 W, single phase, 50/60 Hz
HousingPowder-coated steel with aluminium filter frame
Filter AccessRoom-side with dust collector pan
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Applications

Designed for compact isolation rooms, cleanroom renovation enclosures and localized equipment-repair containment. The 16 in width is particularly useful between congested ceiling services.

Solutions for Your Application

A standard exhaust module cannot fit the narrow ceiling opening.Use the 15.7 in wide cabinet and keep the room-side filter face accessible.
Dust may fall during filter service.Retain the integral collection pan and follow a controlled room-side removal sequence.

Các tùy chọn có sẵn

Choose ceiling frame, duct adapter, filter alarm, suspension hardware and control panel. Balance the variable-speed exhaust against replacement air.