Pemasok One-Stop Anda untuk Peralatan Cleanroom dan Fasilitas Aseptik EsensialDukungan proyek internasional
Open mobile navigationClose mobile navigation
Beranda / Produk / Cleanroom HVAC Systems / Induced-Draft Counterflow Cooling Tower 723-Ton Tall Double-Cell
STJH-INDUCED-DRAFT-COOLING-TOWER-723TON

Induced-Draft Counterflow Cooling Tower 723-Ton Tall Double-Cell

A tall 723-ton double-cell counterflow tower with an 11 ft 2 in thermal section and 183860 CFM induced airflow.
  • 723 nominal tons
  • 11 ft 2 in tower height
  • 183860 CFM induced airflow
Permintaan untuk kutipan Browse Produk

Perkenalan produk

The tallest selected double-cell frame increases thermal depth to 11 ft 2 in while retaining the same plan footprint. Its 40 hp fan system moves 183860 CFM, producing a 723-ton rating for large process chiller plants.

Fitur utama:

Deeper thermal section

The taller fill and air path increase heat-transfer opportunity beyond the two lower-height variants.

Highest selected tower airflow

The 183860 CFM fan duty supports the maximum nominal rating in this footprint family.

Large two-cell configuration

Two cells retain staging and service flexibility for a high-capacity condenser-water plant.

Parameter teknis

Nominal Tonnage723 tons
Cell Quantity2
Fan Motor Selection40 hp class
Fan Airflow183860 CFM
Dimensions17 ft 3 in x 18 ft 1 in x 11 ft 2 in
Tower TypeInduced-draft counterflow
Thermal SectionDeep high-capacity fill section
Water CircuitOpen evaporative condenser water
InstallationOutdoor engineered support
Customization (Kustomisasi)Fan package, materials and water-management accessories can be configured for the intended application and operating environment.

Applications

Large clean-manufacturing process chiller plants, campus condenser-water systems and high-capacity central utilities.

Solutions for Your Application

The required tower duty exceeds the lower-height options within the available plan area.Use the 11 ft 2 in thermal section and verify the 723-ton selection at actual design temperatures.
The taller tower increases wind, structure and maintenance-access considerations.Design anchorage, support, ladders and guardrails around the complete operating and environmental loads.

Pilihan yang tersedia

Structural upgrades, access platform, low-sound fan, VFDs, basin heaters, stainless components, drift control and water-management package can be selected.

Planning a Induced-Draft Counterflow Cooling Tower 723-Ton Tall Double-Cell specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah

Beranda

Produk

Berita

Tentang Kami

Hubungi Kami