Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Trang chủ / Sản phẩm / Cleanroom HVAC Systems / Induced-Draft Counterflow Cooling Tower 723-Ton Tall Double-Cell
STJH-INDUCED-DRAFT-COOLING-TOWER-723TON

Induced-Draft Counterflow Cooling Tower 723-Ton Tall Double-Cell

A tall 723-ton double-cell counterflow tower with an 11 ft 2 in thermal section and 183860 CFM induced airflow.
  • 723 nominal tons
  • 11 ft 2 in tower height
  • 183860 CFM induced airflow
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

The tallest selected double-cell frame increases thermal depth to 11 ft 2 in while retaining the same plan footprint. Its 40 hp fan system moves 183860 CFM, producing a 723-ton rating for large process chiller plants.

Các tính năng chính

Deeper thermal section

The taller fill and air path increase heat-transfer opportunity beyond the two lower-height variants.

Highest selected tower airflow

The 183860 CFM fan duty supports the maximum nominal rating in this footprint family.

Large two-cell configuration

Two cells retain staging and service flexibility for a high-capacity condenser-water plant.

Thông số kỹ thuật

Nominal Tonnage723 tons
Cell Quantity2
Fan Motor Selection40 hp class
Fan Airflow183860 CFM
Dimensions17 ft 3 in x 18 ft 1 in x 11 ft 2 in
Tower TypeInduced-draft counterflow
Thermal SectionDeep high-capacity fill section
Water CircuitOpen evaporative condenser water
InstallationOutdoor engineered support
Tùy chỉnhFan package, materials and water-management accessories can be configured for the intended application and operating environment.

Applications

Large clean-manufacturing process chiller plants, campus condenser-water systems and high-capacity central utilities.

Solutions for Your Application

The required tower duty exceeds the lower-height options within the available plan area.Use the 11 ft 2 in thermal section and verify the 723-ton selection at actual design temperatures.
The taller tower increases wind, structure and maintenance-access considerations.Design anchorage, support, ladders and guardrails around the complete operating and environmental loads.

Các tùy chọn có sẵn

Structural upgrades, access platform, low-sound fan, VFDs, basin heaters, stainless components, drift control and water-management package can be selected.

Planning a Induced-Draft Counterflow Cooling Tower 723-Ton Tall Double-Cell specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Nói chuyện với đội ngũ của chúng tôi
Email cho chúng tôi WhatsApp WeChat