Filtration follows the work area
A relocatable cabinet can support a changed bench arrangement without extending the permanent duct system.
This mobile purifier brings staged particle filtration into a room that needs additional recirculation capacity without another ceiling connection. The upright metal enclosure groups the intake, filter compartments, fan and upper outlet in a relocatable cabinet. A caster base lets the operating position change with benches and temporary work areas, while service access is arranged around the replaceable filters. Cabinet finish, fan control and an optional gas-phase stage can be selected for the intended cleaning routine.
A relocatable cabinet can support a changed bench arrangement without extending the permanent duct system.
Accessible first stages allow accumulated lint and dust to be removed before replacing the final HEPA pack.
Stepped or variable controls let the available filtration duty be chosen for the room's operating period.
A separate molecular cassette can be specified when the identified contaminant needs more than particle filtration.
A movable purifier is useful when the room layout changes, provided its actual air path and service space remain usable.
Common construction and component choices for a mobile room-air cleaner. Cabinet formats, supply versions and filter packages are selected together.
| Format peralatan | Floor-standing, caster-mounted room-air recirculation cabinet |
|---|---|
| Common Metal-Cabinet Reference Formats | 550 × 302 × 783 mm or 702 × 373 × 987 mm (W × D × H) |
| Common Mains-Supply Versions | 115–120 V AC, 60 Hz, or 220–240 V AC, 50/60 Hz, with the matching electrical version |
| Final-Filter Choice | HEPA H13 filtration package |
| Prefiltration Choices | Replaceable coarse or fine-particle prefilter stages ahead of the final filter |
| Fan-Speed Options | Stepped speed selection or continuously adjustable airflow control |
| Cabinet Construction Options | Powder-coated steel or stainless steel |
| Room-Air Path | Lower intake and upper filtered-air discharge on the upright configuration |
| Mobilitas | Caster base with parking brakes |
| Optional Gas-Phase Stage | Molecular-filter cassette selected for the identified gas or odour |
| Operating Indication Options | Local fan-setting display and filter-service indication |
| Layanan pengaturan | Separate access to replaceable filter stages and the fan compartment |
| Customization (Kustomisasi) | Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi. |
The standard selection is a mobile particulate-air recirculator. Ducted supply/exhaust, a gas-phase stage and additional controls are separate configurations rather than functions provided by the HEPA label alone.
Compare the airflow available with the selected filters against the room volume and intended supplemental air-change rate. Gross fan delivery is not automatically clean-air delivery rate, and recirculation does not replace outside-air ventilation or establish a classified cleanroom by itself. Keep airflow, electrical input and sound readings tied to the same filter package and fan setting.
A free space for the casters is not enough if a bench blocks the lower return or the upper discharge flows straight back into the intake. Leave room around the grille and check the operating position after moving the cabinet. Route the power lead away from carts, doors and cleaning paths, then apply the parking brakes.
The HEPA stage addresses airborne particles. A carbon or other molecular cassette is a separate selection based on the contaminant and media capacity, not a universal treatment for vapours. Adding another stage changes resistance and useful airflow, so compare the complete installed stack rather than an unloaded fan figure.
Allow the largest cassette to be withdrawn without removing nearby furniture. Choose the actual supply variant, fan control, display and service indicator as one equipment package. Where the floor must remain clear, compare the wall-mounted cleanroom air purifier; a bracketed installation has different support and access requirements.
Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.