클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
홈 / 제품 / 클린룸 장비 모바일 클린룸 공기 청정기
FFU 및 터미널 공기 정화 장비

모바일 클린룸 공기 정화기

A caster-mounted room-air filtration unit with accessible prefilters, a HEPA final stage and an upper outlet for supplemental recirculation without permanent ductwork.
  • Relocatable Room Filtration
  • Accessible Filter Stages
  • Adjustable Fan Settings
  • Upper Air Discharge
견적 요청 제품 찾아보기

상품 소개

This mobile purifier brings staged particle filtration into a room that needs additional recirculation capacity without another ceiling connection. The upright metal enclosure groups the intake, filter compartments, fan and upper outlet in a relocatable cabinet. A caster base lets the operating position change with benches and temporary work areas, while service access is arranged around the replaceable filters. Cabinet finish, fan control and an optional gas-phase stage can be selected for the intended cleaning routine.

주요 기능

Filtration follows the work area

A relocatable cabinet can support a changed bench arrangement without extending the permanent duct system.

Prefilters can be serviced separately

Accessible first stages allow accumulated lint and dust to be removed before replacing the final HEPA pack.

Operating setting can be selected

Stepped or variable controls let the available filtration duty be chosen for the room's operating period.

Particle and gas stages stay distinct

A separate molecular cassette can be specified when the identified contaminant needs more than particle filtration.

응용 프로그램 솔루션

A movable purifier is useful when the room layout changes, provided its actual air path and service space remain usable.

The area needing extra filtration changes between production activities.Move the cabinet to the selected room and position both grilles clear of benches, stored material and door traffic.
The final filter is replaced while a loaded prefilter remains in place.Make each upstream stage accessible and include it in the service routine before assessing the complete filter stack.
A filter-loading indicator is mistaken for proof of room cleanliness.Use its actual pressure or service-time function for maintenance, and assess the room separately using the intended particle-control method.
A parking position blocks cleaning access or creates a cable crossing.Reserve a defined operating bay, secure the wheels and route the lead outside the normal movement path.

일반적인 응용 프로그램

Supplemental cleanroom recirculationLaboratory particle-control supportMedical-device product inspectionTemporary controlled work areasClean storage and preparation rooms

기술 매개변수

Common construction and component choices for a mobile room-air cleaner. Cabinet formats, supply versions and filter packages are selected together.

장비 형식Floor-standing, caster-mounted room-air recirculation cabinet
Common Metal-Cabinet Reference Formats550 × 302 × 783 mm or 702 × 373 × 987 mm (W × D × H)
Common Mains-Supply Versions115–120 V AC, 60 Hz, or 220–240 V AC, 50/60 Hz, with the matching electrical version
Final-Filter ChoiceHEPA H13 filtration package
Prefiltration ChoicesReplaceable coarse or fine-particle prefilter stages ahead of the final filter
Fan-Speed OptionsStepped speed selection or continuously adjustable airflow control
Cabinet Construction OptionsPowder-coated steel or stainless steel
Room-Air PathLower intake and upper filtered-air discharge on the upright configuration
이동성Caster base with parking brakes
Optional Gas-Phase StageMolecular-filter cassette selected for the identified gas or odour
Operating Indication OptionsLocal fan-setting display and filter-service indication
Service ArrangementSeparate access to replaceable filter stages and the fan compartment
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Coated-steel or stainless cabinetAlternative prefilter/final-filter packageContaminant-selected molecular cassetteStepped or variable fan controlLocal display and service indicationAlternative caster and brake arrangement

The standard selection is a mobile particulate-air recirculator. Ducted supply/exhaust, a gas-phase stage and additional controls are separate configurations rather than functions provided by the HEPA label alone.

Selection and Installation

Base selection on room volume

Compare the airflow available with the selected filters against the room volume and intended supplemental air-change rate. Gross fan delivery is not automatically clean-air delivery rate, and recirculation does not replace outside-air ventilation or establish a classified cleanroom by itself. Keep airflow, electrical input and sound readings tied to the same filter package and fan setting.

Position the intake and outlet together

A free space for the casters is not enough if a bench blocks the lower return or the upper discharge flows straight back into the intake. Leave room around the grille and check the operating position after moving the cabinet. Route the power lead away from carts, doors and cleaning paths, then apply the parking brakes.

Choose particle and gas filtration separately

The HEPA stage addresses airborne particles. A carbon or other molecular cassette is a separate selection based on the contaminant and media capacity, not a universal treatment for vapours. Adding another stage changes resistance and useful airflow, so compare the complete installed stack rather than an unloaded fan figure.

Reserve space for filter replacement

Allow the largest cassette to be withdrawn without removing nearby furniture. Choose the actual supply variant, fan control, display and service indicator as one equipment package. Where the floor must remain clear, compare the wall-mounted cleanroom air purifier; a bracketed installation has different support and access requirements.

모바일 클린룸 공기 정화기 사양을 계획하십니까?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat

홈

제품

뉴스

About Us

연락처