Unit Penanganan Udara Pemulihan Panas
- Separated Supply and Exhaust
- Selectable Recovery Technology
- Bypass and Frost Control
- Reduced Outdoor-Air Load
Perkenalan produk
The heat recovery air handling unit brings outdoor supply and building exhaust through a common insulated casing while maintaining defined separation between air streams. Counterflow plate exchangers offer no moving transfer surface, rotary wheels provide high sensible and latent recovery where appropriate, and run-around coils completely separate the ducts. Bypass dampers, frost control and independent fans keep airflow stable through changing outdoor conditions. The recovery method is chosen according to contamination-transfer tolerance, humidity objectives and physical duct arrangement.
Fitur utama:
Independent supply and exhaust fans maintain balanced airflow through different filter-loading conditions.
Bypass and frost-control sequences protect the exchanger during extreme ambient operation.
Accessible recovery cassettes and drain sections simplify inspection and cleaning.
Solusi untuk aplikasi Anda
Energy recovery is valuable only when cross-stream leakage, frost, condensate and fan balance are controlled for the actual exhaust source.
Aplikasi yang Tipis
Parameter teknis
Representative casing data for a dual-stream heat-recovery air handling unit are shown below.
| Bahan inti | Closed-cell polyurethane or mineral-wool insulation in separated double-skin air paths |
|---|---|
| Ketebalan Panel (Panel Thickness) | 50–60 mm insulated casing |
| Efektif lebar | 1000–3200 mm nominal unit width |
| Panjang maksimum | Up to 10000 mm including recovery, filter, coil and fan sections |
| Baja menghadap ketebalan | 0.6–1.0 mm galvanized, coated or stainless sheet skins |
| Kepadatan inti (core density) | 40–44 kg/m³ polyurethane or 86–100 kg/m³ mineral wool |
| Konduktivitas Termal (Thermal Conductivity) | 0.022–0.040 W/(m·K) for the casing insulation |
| Permukaan selesai | Powder-coated exterior with cleanable galvanized or stainless inner lining |
| Jenis Bersama | Gasketed dual-stream casing with sealed recovery cassette and independent duct collars |
| Customization (Kustomisasi) | Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi. |
Pilihan yang tersedia
Planning a Heat Recovery Air Handling Unit specification?
Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bahasa Inggris
Bahasa Portugis
Bahasa Spanyol
Bahasa Melayu
Bahasa IndonesiaSaat ini
Bahasa Jerman
Bahasa Turki
Bahasa Vietnam
Bahasa Perancis: Bahasa Perancis
Bahasa Rusia
Bahasa Arab
Bahasa Thailand
Bahasa Jepang
Bahasa Korea