Pemulihan haba Unit Pengendalian Udara
- Separated Supply and Exhaust
- Selectable Recovery Technology
- Bypass and Frost Control
- Reduced Outdoor-Air Load
Pengenalan Produk
The heat recovery air handling unit brings outdoor supply and building exhaust through a common insulated casing while maintaining defined separation between air streams. Counterflow plate exchangers offer no moving transfer surface, rotary wheels provide high sensible and latent recovery where appropriate, and run-around coils completely separate the ducts. Bypass dampers, frost control and independent fans keep airflow stable through changing outdoor conditions. The recovery method is chosen according to contamination-transfer tolerance, humidity objectives and physical duct arrangement.
Ciri-ciri Utama
Independent supply and exhaust fans maintain balanced airflow through different filter-loading conditions.
Bypass and frost-control sequences protect the exchanger during extreme ambient operation.
Accessible recovery cassettes and drain sections simplify inspection and cleaning.
Penyelesaian untuk permohonan anda
Energy recovery is valuable only when cross-stream leakage, frost, condensate and fan balance are controlled for the actual exhaust source.
Permohonan yang biasa
Parameter teknikal
Representative casing data for a dual-stream heat-recovery air handling unit are shown below.
| Bahan Teras | Closed-cell polyurethane or mineral-wool insulation in separated double-skin air paths |
|---|---|
| Ketebalan Panel | 50–60 mm insulated casing |
| Lebar berkesan | 1000–3200 mm nominal unit width |
| Panjang maksimum | Up to 10000 mm including recovery, filter, coil and fan sections |
| Keluli Menghadapi Ketebalan | 0.6–1.0 mm galvanized, coated or stainless sheet skins |
| Ketumpatan teras | 40–44 kg/m³ polyurethane or 86–100 kg/m³ mineral wool |
| Kekonduksian Terma | 0.022–0.040 W/(m·K) for the casing insulation |
| Kemasan permukaan | Powder-coated exterior with cleanable galvanized or stainless inner lining |
| Jenis Bersatu | Gasketed dual-stream casing with sealed recovery cassette and independent duct collars |
| Penyesuaian | Boleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi. |
Pilihan yang boleh didapati
Planning a Heat Recovery Air Handling Unit specification?
Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Bahasa Inggeris
Bahasa Portugis: Bahasa Portugis: Bahasa Portugis
Bahasa Sepanyol: Bahasa Sepanyol: Bahasa Sepanyol
Bahasa Melayu (Bahasa Melayu)Semasa
Bahasa Indonesia: Bahasa Indonesia
Bahasa Jerman
Bahasa Turki: Bahasa Turki
Bahasa Vietnam (Bahasa Melayu)
Bahasa Perancis
Bahasa Rusia
Bahasa Arab (Bahasa Melayu)
Bahasa Melayu (Bahasa Melayu)
Bahasa Jepun
Bahasa Korea (Bahasa Melayu)