Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Accueil / Produits / Équipement Cleanroom / Laminar Flow Canopy 3000 × 2000 mm Rectangular
STJH-LAMINAR-FLOW-CANOPY-3000X2000

Laminar Flow Canopy 3000 × 2000 mm Rectangular

A rectangular softwall canopy designed to follow long benches, linear inspection fixtures and narrow production cells.
  • 3 m long protected span
  • 6 m² rectangular floor area
  • Positive H14 HEPA downflow
Demander un devis. Browse les produits

Introduction de produit

This 3000 x 2000 x 2350 mm canopy extends clean-air coverage along a three-metre process while limiting depth to two metres. Ceiling clean-air modules deliver H14 HEPA-filtered downflow within clear curtains, producing a positive localized zone. The rectangular geometry is better suited to linear assembly or inspection than the square canopies in the same family.

Key Features

Linear process fit

The elongated plan follows long workbenches and staged assembly sequences without excess side depth.

Visible softwall boundary

Clear curtains define the clean zone while allowing staff to observe the entire line.

Scalable overhead filtration

Clean-air module quantity can be distributed along the three-metre span to suit equipment blockage.

Paramètres techniques

Overall Dimensions3000 W x 2000 D x 2350 H mm
Protected Floor Area6 m²
Airflow DirectionVertical laminar downflow
Pressure ModeLocalized positive pressure
Final FilterH14 HEPA
Published Filter Efficiency99.97% at 0.3 µm
Wall MaterialClear flexible curtains
LayoutRectangular linear-process enclosure
ConstructionModular and scalable
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Applications

For electronics assembly, medical-device inspection and research benches arranged in a linear three-metre work cell. Map ceiling modules around tall fixtures to maintain coverage along the full span.

Solutions for Your Application

A square canopy wastes floor area beside a long narrow process.Use the 3000 x 2000 mm rectangle to align the clean zone with the bench length.
Tall fixtures interrupt downflow at points along the line.Position filtration modules and critical operations so wakes do not fall onto downstream work.

Options disponibles

Select clean-air module coverage, curtain openings, mobile or fixed base, lighting and utility access. The frame can be lengthened or divided around the production sequence.

Planning a Laminar Flow Canopy 3000 × 2000 mm Rectangular specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact