Unité de filtre de ventilateur standard
- Blower intégré et filtre final
- ZFormat modulaire Ceiling-Grid
- Intake Prefiltration
- Top-Side Fan Access
Introduction de produit
The standard fan filter unit packages a backward-curved centrifugal blower, shallow pressure plenum, mini-pleat final filter and perforated diffuser in one ceiling-mounted housing. Air enters through the top prefilter, passes through the distribution plenum and final filter, and leaves through the downstream face. A perimeter flange and gasket form the interface with the supporting grid. The fan is serviced from above; the final-filter replacement route depends on the selected filter-release configuration.
Key Features
Les déflecteurs internes distribuent l'air à travers le pack mini-plets au lieu de concentrer la vitesse directement en dessous de l'entrée du ventilateur.
ZLa face perforée en aval protège le milieu filtrant et modère le modèle d'air de sortie.par
Une bride de plafond jointe limite le contournement entre le cadre FFU et la grille de support.par
Des solutions pour votre application
Selecting a standard FFU involves the ceiling interface, airflow balance and access to consumable filters.
Les applications typiques
Paramètres techniques
Common grid formats and configurable electrical and filtration choices complement the standard ceiling-module construction below.
| Common Nominal Ceiling Formats | 600 × 600 mm and 600 × 1200 mm grid modules |
|---|---|
| Typical Overall Depth | Approximately 230–320 mm for conventional ceiling FFU configurations |
| Construction du boîtier | Galvanized steel with a white epoxy-polyester powder coating |
| Blower Type | Backward-curved centrifugal blower |
| Filtration Arrangement | Removable intake prefilter and glass-fibre mini-pleat final filter |
| Options de filtre final | H13 or H14 HEPA; U15 ULPA configuration optional |
| Common Power Supply Options | 220–240 V AC, single phase; 50 Hz or 60 Hz electrical variants |
| Air Outlet | Perforated downstream diffuser |
| Ceiling Mounting and Sealing | Drop-in T-grid flange with a continuous perimeter gasket and sealed filter-to-housing interface |
| Control Options | Individual fan-speed adjustment or group-control connection |
| Accès au service | Top-side fan access; clean-side filter release available as an option |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
List the selected module dimensions, filter and controls in the quotation so the supplied configuration is clear.
Selection and Installation
Size the ceiling bay and service space
Send the ceiling-grid opening, support detail, available plenum height and intended access route. Identify whether the unit draws from a common plenum or connects to ductwork. The module envelope, flange bearing and prefilter access need to suit the actual ceiling, not just its nominal grid size.
Specify the operating point
State the required airflow and available inlet conditions, together with the selected final filter. Request input power and sound data at that same duty point; motor nameplate power is not a substitute for operating consumption. For comparison within the range, review the locally controlled AC FFU et EC-motor FFU without assuming that this standard version uses either drive.
Identify what is included
The described module contains the housing, blower, intake prefilter, final filter and diffuser. Specify the required supply voltage, phase and frequency, final-filter grade, controller and cable connection in the enquiry. Group interfaces and clean-side filter release are choices, not implied standard equipment.
Plan balancing and maintenance
Match the fan-control method to any upstream airflow control. Measure supply airflow after installation and after changes to the filter or fan setting. Keep the top fan and prefilter service route clear; choose clean-side filter release where overhead access is impractical. Isolate electrical power before servicing, protect filter media from handling damage and verify the replacement filter seal before returning the area to use. The FFU is a room air-supply component, not a complete ventilation or containment system.
ZPlanifier une unité de filtre de ventilateur standard ?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Le portugais
espagnol
Le malais
Indonésien
Allemand
Le turc
Le vietnamien
FrançaisCurrent
russe
Arabe
Thaïlandais
Japonais
Coréen