موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
الرئيسية / المنتجات / معدات الغرف النظيفة / Laminar Flow Canopy 3000 × 2000 mm Rectangular
STJH-LAMINAR-FLOW-CANOPY-3000X2000

Laminar Flow Canopy 3000 × 2000 mm Rectangular

A rectangular softwall canopy designed to follow long benches, linear inspection fixtures and narrow production cells.
  • 3 m long protected span
  • 6 m² rectangular floor area
  • Positive H14 HEPA downflow
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This 3000 x 2000 x 2350 mm canopy extends clean-air coverage along a three-metre process while limiting depth to two metres. Ceiling clean-air modules deliver H14 HEPA-filtered downflow within clear curtains, producing a positive localized zone. The rectangular geometry is better suited to linear assembly or inspection than the square canopies in the same family.

الخصائص الرئيسية

Linear process fit

The elongated plan follows long workbenches and staged assembly sequences without excess side depth.

Visible softwall boundary

Clear curtains define the clean zone while allowing staff to observe the entire line.

Scalable overhead filtration

Clean-air module quantity can be distributed along the three-metre span to suit equipment blockage.

المعلمات الفنية

Overall Dimensions3000 W x 2000 D x 2350 H mm
Protected Floor Area6 m²
Airflow DirectionVertical laminar downflow
Pressure ModeLocalized positive pressure
Final FilterH14 HEPA
Published Filter Efficiency99.97% at 0.3 µm
Wall MaterialClear flexible curtains
LayoutRectangular linear-process enclosure
ConstructionModular and scalable
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

For electronics assembly, medical-device inspection and research benches arranged in a linear three-metre work cell. Map ceiling modules around tall fixtures to maintain coverage along the full span.

Solutions for Your Application

A square canopy wastes floor area beside a long narrow process.Use the 3000 x 2000 mm rectangle to align the clean zone with the bench length.
Tall fixtures interrupt downflow at points along the line.Position filtration modules and critical operations so wakes do not fall onto downstream work.

الخيارات المتاحة

Select clean-air module coverage, curtain openings, mobile or fixed base, lighting and utility access. The frame can be lengthened or divided around the production sequence.

Planning a Laminar Flow Canopy 3000 × 2000 mm Rectangular specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا