Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Accueil / Produits / Containment & Biosafety Equipment / Class III Biological Safety Cabinet 3-Glove 1372 mm
STJH-CLASS-III-BIOLOGICAL-SAFETY-CABINET-3G-1372

Class III Biological Safety Cabinet 3-Glove 1372 mm

A three-glove Class III cabinet that adds a central handling position across a 1372 mm sealed work chamber.
  • Three glove positions
  • 1372 mm internal width
  • Double exhaust HEPA
Demander un devis. Browse les produits

Introduction de produit

The intermediate chamber adds 305 mm of working width and a third glove position over the compact model. That layout supports a left-to-right sequence for receipt, manipulation and staging without the floor span of the four-glove cabinet.

Key Features

Sequential task layout

Three access positions let operators assign separate zones to preparation, active handling and completed material.

Leak-tight isolation

Sanitary shut-off valves on inlet and exhaust support closure of the filtered chamber.

Ergonomic viewing plane

A sloped clear window improves sightlines across the deeper middle work position.

Paramètres techniques

Work-Zone Dimensions1372 x 559 x 743 mm
Overall Dimensions1836 x 629 x 1940 mm including stand
Glove Ports3 angled stainless ports
Cabinet ClassClass III biological safety cabinet
Operating PressureNegative relative to the room
Supply FiltrationSingle HEPA stage
Exhaust FiltrationDouble HEPA stages
Viewing Window9.5 mm coated clear polycarbonate, nominal 5–7° slope
Interior FinishPolished stainless steel with coved corners
CustomisationTransfer device, glove specification, utility penetrations and blower arrangement can be adapted to the operating procedure.

Applications

Multi-step pathogen research, vaccine-development support and virology procedures that benefit from three distinct manipulation positions.

Solutions for Your Application

A two-glove chamber forces instruments to share the primary handling area.Use the third access position to separate equipment operation from sample transfer and finishing tasks.
Interior shutdown must not rely on exposed temporary closures.Select the sanitary inlet and exhaust shut-off arrangement for a defined leak-tight isolation state.

Options disponibles

Airlock side and purge, glove type and size, VHP ports, blower location, utilities and mobile base are configurable.

Planning a Class III Biological Safety Cabinet 3-Glove 1372 mm specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact