موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
الرئيسية / المنتجات / Containment & Biosafety Equipment / Class III Biological Safety Cabinet 3-Glove 1372 mm
STJH-CLASS-III-BIOLOGICAL-SAFETY-CABINET-3G-1372

Class III Biological Safety Cabinet 3-Glove 1372 mm

A three-glove Class III cabinet that adds a central handling position across a 1372 mm sealed work chamber.
  • Three glove positions
  • 1372 mm internal width
  • Double exhaust HEPA
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The intermediate chamber adds 305 mm of working width and a third glove position over the compact model. That layout supports a left-to-right sequence for receipt, manipulation and staging without the floor span of the four-glove cabinet.

الخصائص الرئيسية

Sequential task layout

Three access positions let operators assign separate zones to preparation, active handling and completed material.

Leak-tight isolation

Sanitary shut-off valves on inlet and exhaust support closure of the filtered chamber.

Ergonomic viewing plane

A sloped clear window improves sightlines across the deeper middle work position.

المعلمات الفنية

Work-Zone Dimensions1372 x 559 x 743 mm
Overall Dimensions1836 x 629 x 1940 mm including stand
Glove Ports3 angled stainless ports
Cabinet ClassClass III biological safety cabinet
Operating PressureNegative relative to the room
Supply FiltrationSingle HEPA stage
Exhaust FiltrationDouble HEPA stages
Viewing Window9.5 mm coated clear polycarbonate, nominal 5–7° slope
Interior FinishPolished stainless steel with coved corners
التخصيصTransfer device, glove specification, utility penetrations and blower arrangement can be adapted to the operating procedure.

Applications

Multi-step pathogen research, vaccine-development support and virology procedures that benefit from three distinct manipulation positions.

Solutions for Your Application

A two-glove chamber forces instruments to share the primary handling area.Use the third access position to separate equipment operation from sample transfer and finishing tasks.
Interior shutdown must not rely on exposed temporary closures.Select the sanitary inlet and exhaust shut-off arrangement for a defined leak-tight isolation state.

الخيارات المتاحة

Airlock side and purge, glove type and size, VHP ports, blower location, utilities and mobile base are configurable.

Planning a Class III Biological Safety Cabinet 3-Glove 1372 mm specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا