Bồn tắm không khí phòng sạch ba cửa
- Three Controlled Doorways
- Branched Personnel Routing
- Selectable Clean-Side Exit
- Shared Cleaning Zone
Giới thiệu Sản phẩm
The three-door air shower introduces a third doorway to a common cleaning chamber. Its enclosure combines door frames, nozzle panels, return grilles and an accessible blower/filter section around the available wall area. In a destination-selective configuration, the controller coordinates the selected exit with the closed-door signals and cleaning cycle. This lets one gowning entrance serve two controlled zones or a T-shaped circulation plan without duplicating the whole shower enclosure.
Các tính năng chính
Exit selection can be linked to the required destination path.
Centralised nozzle coverage serves the shared cleaning space.
Branch-aware status indication
Door and cycle signals can distinguish a selected destination from a busy or unavailable branch.
Layout-specific maintenance access
Removable panels allow service positions to be selected without reserving every chamber wall for equipment access.
Các giải pháp cho ứng dụng của bạn
The extra doorway is useful when destination rules are as clear as the physical route.
Các ứng dụng điển hình
Thông số kỹ thuật
The following are selectable three-door air-shower references, not a single tested STjh model schedule. Compact footprint and nominal door-width examples describe one published three-door family; other manufacturers corroborate the configuration but use different sizes.
| Sắp xếp cửa | Three controlled doorways around one personnel cleaning chamber |
|---|---|
| Typical Routing | One gowning entrance and two destination exits; left-hand or right-hand branch arrangement |
| Compact Footprint References | 1264 x 1372 mm or 1264 x 1829 mm, enclosure width x depth |
| Nominal Door Width Reference | 914 mm; actual clear passage depends on the selected frame and leaf |
| Housing Options | Powder-coated steel or Type 304 stainless steel |
| Filtration Arrangement | Return-air prefilters and a final HEPA filter in a recirculating air circuit |
| Cleaning Outlets | Adjustable wall nozzles with optional supplementary ceiling nozzles |
| Common Cycle-Timer Option | 0-99 s adjustable run-time range |
| Post-Cycle Wait Option | 0-10 s adjustable delay before normal exit release |
| Common Supply Option | 208 V AC, 60 Hz, three phase; alternative regional supplies available |
| Access-Control Options | Door-position monitoring, electronic interlocks and destination-selective release |
| Sắp xếp dịch vụ | Removable nozzle-wall or ceiling access panels, depending on blower and filter position |
| Tùy chỉnh | Có sẵn dựa trên ứng dụng dự định và môi trường hoạt động. |
Các tùy chọn có sẵn
Common construction includes the shared recirculation chamber, filter stages and timed controller. Destination permissions, powered doors, special exit sequencing and external safety interfaces are separate selections. A card-reader input controls permission; it does not by itself define the door interlock or emergency behavior.
Selection and Installation
Define which rooms may share the chamber
Identify the gowning side, each destination and the permitted return paths. Two clean-side connections do not automatically make different processes compatible. Review garment policy, pressure relationships and contamination sensitivity before using one chamber for both rooms. A common air circuit does not provide independent containment between destinations.
Write a route-by-route door sequence
Choose how the destination is selected and which door becomes available after the cycle and any wait period. In a destination-selective arrangement, the unused branch remains closed during normal travel. Define what happens when another person requests the other route, a door does not reach its closed position or a cycle is interrupted. Do not assume every door may be opened together or used freely in both directions.
Separate routine access from emergency response
Normal interlocking and security permissions are different from emergency release. Select the actual manual-release, alarm and power-loss functions for all three openings, including their connection to the building's safety arrangements. The third door is not automatically a dedicated emergency exit, and a route-selection controller alone does not establish compliant evacuation.
Fit the whole three-door junction
Allow space for each door leaf, queue and destination corridor, plus the filter and blower service route. Nominal door width is not measured clear opening. Keep outlets and returns clear of door frames and users waiting at a branch. Choose occupancy from the usable chamber area and operating sequence, not the number of doors. If only one corner connection is needed, compare the L-shaped air shower; if entry and exit share one wall, compare the U-shaped return-route air shower.
Planning a Three-Door Cleanroom Air Shower specification?
Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Tiếng Anh
Tiếng Bồ Đào Nha, tiếng Bồ Đào Nha
Tiếng Tây Ban Nha, tiếng Tây Ban Nha
Tiếng Mã Lai
Tiếng Indonesia (tiếng Việt)
Tiếng Đức, tiếng Đức
Tiếng Thổ Nhĩ Kỳ, tiếng Thổ Nhĩ Kỳ
Tiếng Việt / tiếng ViệtHiện tại
Tiếng Pháp, tiếng Pháp
Tiếng Nga, tiếng Nga
Tiếng Ả Rập, tiếng Ả Rập
Tiếng Thái (tiếng Thái)
Tiếng Nhật
Tiếng Hàn / tiếng Hàn