Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Trang chủ / Sản phẩm / Cleanroom Air Filters / Nuclear-Grade HEPA Filter AG-1 Gel-Seal
STJH-NUCLEAR-HEPA-AG1-GEL

Nuclear-Grade HEPA Filter AG-1 Gel-Seal

A qualified stainless nuclear HEPA cell with a continuous gel trough for compatible positive-seal housings.
  • Continuous gel seal
  • AG-1 qualified microglass
  • Optional extraction clips
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

This nuclear model keeps the rugged Type 304 stainless enclosure and qualified microglass pack but uses a continuous silicone-gel channel instead of a face gasket. The gel interface is useful where the containment frame provides a mating blade and where controlled extraction may be needed during BIBO service. Trough location is available on either airflow face, so orientation must be frozen before manufacturing.

Các tính năng chính

Positive blade engagement

A continuous gel channel surrounds the airflow opening and accepts the housing knife edge without broad gasket compression.

Containment-change compatibility

Optional extraction clips can support filter removal from bag-in/bag-out housings designed for the selected cell.

Protected stainless assembly

Stainless guards on both faces shield the qualified pack while preserving a robust frame for controlled handling.

Thông số kỹ thuật

Minimum Efficiency99.97% at 0.3 micron
Filter MediaASME AG-1 qualified microglass
Frame MaterialType 304 stainless steel
Seal TypeContinuous silicone gel channel
Seal LocationUpstream or downstream as specified
FaceguardsType 304 stainless steel on both faces
Extraction FeatureOptional clips for compatible BIBO housings
Maximum Continuous Temperature121 C
Moisture CapabilityUp to 99% relative humidity
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Applications

Used in nuclear or hazardous containment banks whose approved housing is built around a gel trough and mating knife edge. It is especially relevant where changeout equipment needs extraction clips, but system containment depends on the complete housing and procedure.

Solutions for Your Application

The gel trough is on the opposite face from the housing blade.State upstream or downstream gel location on the order and compare it with the bank airflow drawing before fabrication.
A gel-seal nuclear cell cannot be withdrawn cleanly by the installed BIBO mechanism.Include the housing model and required extraction-clip geometry in the technical review instead of adding improvised handles on site.

Các tùy chọn có sẵn

Define AG-1 size, airflow capacity, gel side, gel-channel construction, extraction clips, guard arrangement and packaging controls.

Planning a Nuclear-Grade HEPA Filter AG-1 Gel-Seal specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Nói chuyện với đội ngũ của chúng tôi
Email cho chúng tôi WhatsApp WeChat

Trang chủ