Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Trang chủ / Sản phẩm / Cleanroom Air Filters / Nuclear-Grade HEPA Filter 2000 CFM AG-1 V-Bank
STJH-NUCLEAR-HEPA-AG1-2000CFM

Nuclear-Grade HEPA Filter 2000 CFM AG-1 V-Bank

A 2000 cfm nuclear V-bank that doubles common 1000 cfm capacity within the standard full-size housing envelope.
  • 2000 cfm rated airflow
  • 24 x 24 x 11.5 inch envelope
  • AG-1 V-bank architecture
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

This Size-8 configuration arranges qualified mini-pleat panels in a V-form to deliver 2000 cfm through a nominal 24 x 24 x 11.5 inch stainless enclosure. It is intended for high-flow retrofits or new banks that need greater capacity per opening, with a published comparable clean resistance near 1.3 in. w.g. The fan, rack strength and upstream flow distribution must all be checked for the higher duty.

Các tính năng chính

More airflow per opening

The V-arranged media area supports 2000 cfm in a standard full-size footprint, reducing the bank face area needed for a given flow.

Retrofit-compatible dimensions

The nominal 24-inch square by 11.5-inch depth targets existing nuclear housings designed for Size-8 geometry.

Qualified high-flow pack

Microfine glass panels, continuous separators and urethane bonding form a protected nuclear-duty airflow path.

Thông số kỹ thuật

AG-1 SizeSize 8
Nominal Dimensions24 x 24 x 11.5 in
Rated Airflow2000 cfm
Initial ResistanceAbout 1.3 in. w.g. at rated airflow
Minimum Efficiency99.97% at 0.3 micron
Filter MediaAG-1 qualified microfine glass mini-pleats
Frame MaterialStainless steel
Seal OptionsGel or gasket
Maximum Continuous Temperature121 C
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Applications

Designed for higher-capacity nuclear power, DOE or defense ventilation trains where a Size-8 cell and 2000 cfm operating point are accepted by the system design. Existing fans and housings should be reviewed for resistance, loading and clamp or gel compatibility before retrofit.

Solutions for Your Application

A 2000 cfm replacement fits physically but overloads the existing fan or creates uneven face velocity.Model the bank at about 1.3 in. w.g. clean resistance and verify approach-air distribution before changing from a lower-flow cell.
The order states Size 8 but omits the housing seal style.Identify gasket or gel interface, seal face and clamp or blade geometry so the high-flow cell does not bypass at installation.

Các tùy chọn có sẵn

Confirm exact external tolerances, gasket or gel seal, seal location, faceguards, airflow orientation and nuclear packaging requirements.

Planning a Nuclear-Grade HEPA Filter 2000 CFM AG-1 V-Bank specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Nói chuyện với đội ngũ của chúng tôi