STJH-NUCLEAR-HEPA-AG1-2000CFM

Nuclear-Grade HEPA Filter 2000 CFM AG-1 V-Bank

A 2000 cfm nuclear V-bank that doubles common 1000 cfm capacity within the standard full-size housing envelope.
  • 2000 cfm rated airflow
  • 24 x 24 x 11.5 inch envelope
  • AG-1 V-bank architecture
견적 요청 제품 찾아보기

상품 소개

This Size-8 configuration arranges qualified mini-pleat panels in a V-form to deliver 2000 cfm through a nominal 24 x 24 x 11.5 inch stainless enclosure. It is intended for high-flow retrofits or new banks that need greater capacity per opening, with a published comparable clean resistance near 1.3 in. w.g. The fan, rack strength and upstream flow distribution must all be checked for the higher duty.

주요 기능

More airflow per opening

The V-arranged media area supports 2000 cfm in a standard full-size footprint, reducing the bank face area needed for a given flow.

Retrofit-compatible dimensions

The nominal 24-inch square by 11.5-inch depth targets existing nuclear housings designed for Size-8 geometry.

Qualified high-flow pack

Microfine glass panels, continuous separators and urethane bonding form a protected nuclear-duty airflow path.

기술 매개변수

AG-1 SizeSize 8
Nominal Dimensions24 x 24 x 11.5 in
Rated Airflow2000 cfm
Initial ResistanceAbout 1.3 in. w.g. at rated airflow
Minimum Efficiency99.97% at 0.3 micron
Filter MediaAG-1 qualified microfine glass mini-pleats
Frame MaterialStainless steel
Seal OptionsGel or gasket
Maximum Continuous Temperature121 C
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

Applications

Designed for higher-capacity nuclear power, DOE or defense ventilation trains where a Size-8 cell and 2000 cfm operating point are accepted by the system design. Existing fans and housings should be reviewed for resistance, loading and clamp or gel compatibility before retrofit.

Solutions for Your Application

A 2000 cfm replacement fits physically but overloads the existing fan or creates uneven face velocity.Model the bank at about 1.3 in. w.g. clean resistance and verify approach-air distribution before changing from a lower-flow cell.
The order states Size 8 but omits the housing seal style.Identify gasket or gel interface, seal face and clamp or blade geometry so the high-flow cell does not bypass at installation.

사용 가능한 옵션

Confirm exact external tolerances, gasket or gel seal, seal location, faceguards, airflow orientation and nuclear packaging requirements.

Planning a Nuclear-Grade HEPA Filter 2000 CFM AG-1 V-Bank specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat

제품

뉴스

회사 소개

문의하기