Trang chủ / Sản phẩm / Thiết bị phòng sạch / Fan Filter Unit 2 × 2 ft Top-Side Explosion-Proof
STJH-EXPLOSION-PROOF-FFU-2X2-TOPSIDE

Fan Filter Unit 2 × 2 ft Top-Side Explosion-Proof

A compact stainless ULPA module for small hazardous-location clean enclosures with top-side service.
  • 2 x 2 ft compact footprint
  • Top-side ULPA filter access
  • Hazardous-location motor enclosure
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

The 2 x 2 ft model is the smallest accepted footprint in this hazardous-location FFU family. Its 23.72 x 23.63 x 19.86 in stainless housing uses top-side ULPA access and a non-sparking motor in a cast-iron explosion-proof enclosure. The unit is organized around the manufacturer's NEC Class I/Class II, Division 1 family construction; suitability for a specific classified area still depends on the complete ordered configuration and site requirements.

Các tính năng chính

Small classified-area format

The square footprint serves compact process enclosures and ceiling bays where a longer unit is unnecessary.

Protected drive assembly

A non-sparking motor is housed in a cast-iron explosion-proof enclosure as part of the cited hazardous-location family.

Top-side maintenance path

The ULPA stage is serviced from above, separating routine access from the clean-air discharge face.

Thông số kỹ thuật

Nominal Module Size2 x 2 ft
External Dimensions23.72 x 23.63 x 19.86 in
Housing MaterialStainless steel
Final FilterULPA
Filter AccessTop side
Electrical Input120/240 V, single phase, 50/60 Hz
Motor ConstructionNon-sparking motor in cast-iron explosion-proof housing
Hazardous-Location Family BasisNEC Class I/Class II, Division 1 construction
Airflow DirectionFiltered positive-pressure supply
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Applications

Intended for compact hazardous dispensing enclosures, solvent-handling clean zones and small classified ceiling bays requiring filtered positive-pressure supply. The area classification, wiring method, seals and complete equipment assembly must be evaluated together for the actual site.

Solutions for Your Application

A standard cleanroom FFU does not address the electrical hazards of the classified area.Use a configuration based on the cited hazardous-location family and have the complete installed system evaluated for the specific area classification.
Room-side filter access could disrupt the small controlled enclosure.Reserve a safe top-side service route for ULPA replacement and motor access.

Các tùy chọn có sẵn

Confirm the classified-area basis, voltage, wiring and isolator arrangement, ULPA seal, stainless finish and ceiling connection. Do not select the module independently from the complete hazardous-location installation.