Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Trang chủ / Sản phẩm / Cleanroom HVAC Systems / Direct-Expansion Cooling Coil Eight-Row
STJH-DIRECT-EXPANSION-COOLING-COIL-8ROW

Direct-Expansion Cooling Coil Eight-Row

The deepest DX evaporator in the group for high latent loads and low leaving-air temperatures.
  • Eight-row maximum depth
  • 13.5 in published casing
  • High-latent counterflow design
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

This eight-row evaporator extends the casing to 13.5 in and carries the greatest selected refrigerant circuit and surface area. Approximately 500 fpm is a common face-velocity basis, subject to wet-coil carryover and performance rating. It is intended for high-outdoor-air and precision-conditioning systems where deeper cooling justifies the greater air pressure drop, condensate production and refrigerant distribution complexity.

Các tính năng chính

Maximum latent capability

The deep cold surface promotes lower leaving temperature and greater moisture removal.

Expanded refrigerant circuiting

Additional parallel circuits distribute capacity across a large evaporator face.

Precision make-up-air duty

The core supports demanding cleanroom supply conditions that shallow DX coils cannot reach.

Thông số kỹ thuật

Tube Rows8
Casing Depth13.5 in
Recommended Face VelocityApproximately 500 fpm
CircuitingCounterflow DX
Tube MaterialCopper for halocarbon refrigerant
Fin MaterialAluminum by standard selection
Refrigerant CircuitsMultiple circuits sized to duty
Condensate ManagementDeep drain pan and optional eliminator
Primary DutyHigh-latent precision cooling
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Applications

For high-latent cleanroom make-up air, low-temperature DX supply systems and precision manufacturing ventilation.

Solutions for Your Application

Oil return becomes unreliable through numerous low-load refrigerant circuits.Size circuit velocity and staging for part-load operation and coordinate distributor and suction-header geometry.
The deep wet core produces unacceptable fan loss and water carryover.Rate the complete coil wet, enlarge face area and add an eliminator where the selected velocity requires it.

Các tùy chọn có sẵn

Confirm refrigerant, load profile, suction conditions, circuits, distributors, face size, fin spacing, coating, casing and drainage.

Planning a Direct-Expansion Cooling Coil Eight-Row specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Nói chuyện với đội ngũ của chúng tôi
Email cho chúng tôi WhatsApp WeChat